{"id":10039,"date":"2024-07-03T08:32:55","date_gmt":"2024-07-03T08:32:55","guid":{"rendered":"https:\/\/www.fibermall.com\/blog\/?p=10039"},"modified":"2024-07-03T08:33:04","modified_gmt":"2024-07-03T08:33:04","slug":"co-packaged-optics-cpo-solutions-for-fiber-interconnect-in-module-packaging","status":"publish","type":"post","link":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm","title":{"rendered":"Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging"},"content":{"rendered":"\n<p>With the surge in demand for computational power driven by AI technologies, major manufacturers are developing new high-speed optical module products to meet the rapidly growing market needs. Considering factors such as size, cost, and power consumption, two concepts gaining prominence are Linear-drive Pluggable Optics (LPO) and Co-Packaged Optics (CPO).<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\/#Internal_Jumper-Type_CPO\" >Internal Jumper-Type CPO<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\/#Optical_Backplane_Approach\" >Optical Backplane Approach<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\/#Conclusion\" >Conclusion<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\/#Related_Posts\" >Related Posts<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\" id=\"h-internal-jumper-type-cpo\"><span class=\"ez-toc-section\" id=\"Internal_Jumper-Type_CPO\"><\/span><strong>Internal Jumper-Type CPO<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>In CPO switches, minimizing electrical interconnects is essential. The fiber routing from optical engines (including transmitters and receivers) to the switch chassis front panel is unavoidable.<\/p>\n\n\n\n<p>Since optical engines (OEs) are positioned around the ASIC, the distance from each OE to the front panel varies, complicating internal fiber routing within the switch.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Internal-Jumper-Type-CPO.png\" alt=\"Internal Jumper-Type CPO\" class=\"wp-image-10042\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Internal-Jumper-Type-CPO.png 692w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Internal-Jumper-Type-CPO-300x205.png 300w\" sizes=\"(max-width: 692px) 100vw, 692px\" \/><\/figure>\n\n\n\n<p>CPO modules, with their multi-channel high-density packaging, require high-precision fiber array (FA), MT, or <a href=\"https:\/\/www.fibermall.com\/store-17112-mpo-trunk-cables.htm\" target=\"_blank\" rel=\"noreferrer noopener\">MPO connectors<\/a>. However, this specification increases the risk of issues like cracks, poor matching, and long-term performance degradation.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/multi-channel-high-density-packaging.png\" alt=\"multi-channel high-density packaging\" class=\"wp-image-10043\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/multi-channel-high-density-packaging.png 679w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/multi-channel-high-density-packaging-300x173.png 300w\" sizes=\"(max-width: 679px) 100vw, 679px\" \/><\/figure>\n\n\n\n<p>Uneven lengths of high-density patch cords pose challenges for manufacturers and increase the risk of fiber damage during installation, especially for longer patch cords.<\/p>\n\n\n\n<p>Many CPO modules produced using the CPO process use FA-type patch cords for internal fiber routing and pluggable connections. However, some manufacturers explore an alternative approach using flexible backplane materials.<\/p>\n\n\n\n<p>This method routes pure bare fibers on a flexible backplane substrate, resulting in a cleaner and more organized internal fiber layout.<\/p>\n\n\n\n<p>Directly connecting bare fibers reduces connector insertion loss and avoids issues related to damaged end faces, dust, and incomplete matching.<\/p>\n\n\n\n<p>Connector manufacturer SENKO addresses these challenges by employing an intermediate board or board-mounted optical interconnect solution.<\/p>\n\n\n\n<p>Using a single length of FA patch cord for coupling with OEs, the other end of the patch cord connects to the front panel using customized fiber adapters (flanges) in a plug-and-play manner.<\/p>\n\n\n\n<p>While this approach introduces additional fiber end-face connections, it significantly improves maintainability, repairability, and cost savings.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/MPC-SENKO-PIC-Connector.png\" alt=\"MPC-SENKO PIC Connector\" class=\"wp-image-10044\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/MPC-SENKO-PIC-Connector.png 608w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/MPC-SENKO-PIC-Connector-300x256.png 300w\" sizes=\"(max-width: 608px) 100vw, 608px\" \/><figcaption class=\"wp-element-caption\">MPC-SENKO PIC Connector<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/MBMC-stackable-MT.png\" alt=\"MBMC stackable MT\" class=\"wp-image-10045\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/MBMC-stackable-MT.png 536w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/MBMC-stackable-MT-300x253.png 300w\" sizes=\"(max-width: 536px) 100vw, 536px\" \/><figcaption class=\"wp-element-caption\">NKO board-to-board connector<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png\" alt=\"Senko\u2019s CPO module internal schematic using board-to-board connectors\" class=\"wp-image-10048\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png 692w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors-300x196.png 300w\" sizes=\"(max-width: 692px) 100vw, 692px\" \/><figcaption class=\"wp-element-caption\">Senko\u2019s CPO module internal schematic using board-to-board connectors<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-optical-backplane-approach\"><span class=\"ez-toc-section\" id=\"Optical_Backplane_Approach\"><\/span><strong>Optical Backplane Approach<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Currently, in the production of high-speed optical modules using Co-Packaged Optics (CPO) technology, the predominant method involves using FA-type patch cords for internal fiber routing and pluggable connections. Additionally, some manufacturers utilize flexible backplane materials as a substrate, installing pure bare fibers on top for routing. Clearly, this approach, which employs end-to-end port connections, results in a cleaner and more organized internal module layout. Furthermore, direct connection using bare fibers reduces connector insertion loss and avoids issues related to damaged end faces, dust, and incomplete matching.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Optical-Backplane-Approach.png\" alt=\"FiberMall\u2019s CPO Internal Wiring Schematic Using Optical Backplane Approach\" class=\"wp-image-10052\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Optical-Backplane-Approach.png 692w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Optical-Backplane-Approach-300x105.png 300w\" sizes=\"(max-width: 692px) 100vw, 692px\" \/><figcaption class=\"wp-element-caption\">FiberMall\u2019s CPO Internal Wiring Schematic Using Optical Backplane Approach<\/figcaption><\/figure>\n\n\n\n<p>Due to the advantages of the fiber flexible backplane approach, FiberMall has been an early adopter of this technique, implementing it in large-scale data centers with the aim of replacing jumper plugging and alleviating cable clutter. However, this technology still needs to address long-term stability and resilience to external environmental interference. Additionally, standardization of port-to-port interfaces and testing metrics across different manufacturers remains a challenge.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Optical-Fiber-Flexible-Backplane.png\" alt=\"Optical Fiber Flexible Backplane\" class=\"wp-image-10056\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Optical-Fiber-Flexible-Backplane.png 597w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Optical-Fiber-Flexible-Backplane-300x205.png 300w\" sizes=\"(max-width: 597px) 100vw, 597px\" \/><figcaption class=\"wp-element-caption\">Optical Fiber Flexible Backplane<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-conclusion\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span><strong>Conclusion<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>While CPO technology holds significant potential for enhancing data center interconnect performance, it also introduces complexities in fiber routing. Industry solutions, such as SENKO\u2019s intermediate board or board-mounted optical interconnect method and the use of flexible backplane materials with bare fibers, offer advantages in reducing losses and simplifying wiring. However, achieving widespread adoption requires overcoming challenges related to long-term stability and standardization.<\/p>\n<style>\r\n\r\n        .lwrp.link-whisper-related-posts{\r\n            \r\n            margin-top: 40px;\nmargin-bottom: 30px;\r\n        }\r\n        .lwrp .lwrp-title{\r\n            \r\n            \r\n        }\r\n        .lwrp .lwrp-description{\r\n            \r\n            \r\n\r\n        }\r\n        .lwrp .lwrp-list-container{\r\n        }\r\n        .lwrp .lwrp-list-multi-container{\r\n            display: flex;\r\n        }\r\n        .lwrp .lwrp-list-double{\r\n            width: 48%;\r\n        }\r\n        .lwrp .lwrp-list-triple{\r\n            width: 32%;\r\n        }\r\n        .lwrp .lwrp-list-row-container{\r\n            display: flex;\r\n            justify-content: space-between;\r\n        }\r\n        .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n            width: calc(100% - 20px);\r\n        }\r\n        .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n            \r\n            list-style: decimal;\r\n        }\r\n        .lwrp .lwrp-list-item img{\r\n            max-width: 100%;\r\n            height: auto;\r\n        }\r\n        .lwrp .lwrp-list-item.lwrp-empty-list-item{\r\n            background: initial !important;\r\n        }\r\n        .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n        .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n            \r\n                \r\n        }\r\n        @media screen and (max-width: 480px) {\r\n            .lwrp.link-whisper-related-posts{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-title{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-description{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-multi-container{\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-multi-container ul.lwrp-list{\r\n                margin-top: 0px;\r\n                margin-bottom: 0px;\r\n                padding-top: 0px;\r\n                padding-bottom: 0px;\r\n            }\r\n            .lwrp .lwrp-list-double,\r\n            .lwrp .lwrp-list-triple{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-row-container{\r\n                justify-content: initial;\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n            .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n                \r\n                    \r\n            }\r\n        }<\/style>\r\n<div id=\"link-whisper-related-posts-widget\" class=\"link-whisper-related-posts lwrp\">\r\n            <h3 class=\"lwrp-title\">Related Posts<\/h3>    \r\n        <div class=\"lwrp-list-container\">\r\n                                            <ul class=\"lwrp-list lwrp-list-single\">\r\n                    <li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/video\/100g-single-lambda-qsfp28.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">100G Single Lambda QSFP28 DR, FR, and LR<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/unifi-switch-aggregation.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Unleash the Power of Ubiquiti Unifi Switch Aggregation<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/questions\/max-power-consumption-of-400g-osfp-qsfp-dd.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">What is the Maximum Power Consumption of 400G OSFP and QSFP-DD Transceivers?<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/questions\/can-osfp-be-plugged-into-qsfp-dd-port.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Can I Plug an OSFP Module into a QSFP-DD Port, or a QSFP-DD Module into an OSFP Port?<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/duplex-lc-connector.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Understanding the Duplex LC Connector: The Go-To Fiber Network Solution<\/span><\/a><\/li>                <\/ul>\r\n                        <\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"<p>With the surge in demand for computational power driven by AI technologies, major manufacturers are developing new high-speed optical module products to meet the rapidly growing market needs. Considering factors such as size, cost, and power consumption, two concepts gaining prominence are Linear-drive Pluggable Optics (LPO) and Co-Packaged Optics (CPO). Internal Jumper-Type CPO In CPO [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":10048,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":"","_wpscppro_dont_share_socialmedia":false,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"default","_instagram_share_type":"default","_medium_share_type":"","_threads_share_type":"","_google_business_share_type":"","_selected_social_profile":[{"id":"skM9ewvR8O","platform":"linkedin","platformKey":0,"name":"Jason Xue","type":"person","thumbnail_url":"https:\/\/media.licdn.com\/dms\/image\/C5603AQErPqKD0j6qBg\/profile-displayphoto-shrink_100_100\/0\/1599138392315?e=1723075200&v=beta&t=joEkh1OeKQ0F-QpAPv4xxQyBdGlHyccIQZauRSs6RvU","share_type":"default"}],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[2,30],"tags":[],"class_list":["post-10039","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-fiber-optic-transceivers"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v20.13 (Yoast SEO v25.8) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging - fibermall.com<\/title>\n<meta name=\"description\" content=\"Many CPO modules produced using the CPO process use FA-type patch cords for internal fiber routing and pluggable connections.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging\" \/>\n<meta property=\"og:description\" content=\"With the surge in demand for computational power driven by AI technologies, major manufacturers are developing new high-speed optical module products to\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\" \/>\n<meta property=\"og:site_name\" content=\"fibermall.com\" \/>\n<meta property=\"article:published_time\" content=\"2024-07-03T08:32:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-03T08:33:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png\" \/>\n\t<meta property=\"og:image:width\" content=\"692\" \/>\n\t<meta property=\"og:image:height\" content=\"453\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Mia\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Mia\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\"},\"author\":{\"name\":\"Mia\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/56a37c7b0e1e8c61823cd6ef48e8dce3\"},\"headline\":\"Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging\",\"datePublished\":\"2024-07-03T08:32:55+00:00\",\"dateModified\":\"2024-07-03T08:33:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\"},\"wordCount\":554,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png\",\"articleSection\":[\"Blog\",\"Fiber Optic Transceivers\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\",\"url\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\",\"name\":\"Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging - fibermall.com\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png\",\"datePublished\":\"2024-07-03T08:32:55+00:00\",\"dateModified\":\"2024-07-03T08:33:04+00:00\",\"description\":\"Many CPO modules produced using the CPO process use FA-type patch cords for internal fiber routing and pluggable connections.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#primaryimage\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png\",\"width\":692,\"height\":453,\"caption\":\"Senkos-CPO-module-internal-schematic-using-board-to-board-connectors\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.fibermall.com\/blog.htm\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"name\":\"fibermall.com\",\"description\":\"Optical Communication Expert\",\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\",\"name\":\"fibermall.com\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"width\":200,\"height\":67,\"caption\":\"fibermall.com\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/56a37c7b0e1e8c61823cd6ef48e8dce3\",\"name\":\"Mia\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/2e83831e57346d5d451c45e43aa96d14fc758d8f72f7304810e123b36585382b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/2e83831e57346d5d451c45e43aa96d14fc758d8f72f7304810e123b36585382b?s=96&d=mm&r=g\",\"caption\":\"Mia\"},\"description\":\"Optical Transmission Consultant\",\"sameAs\":[\"https:\/\/www.fibermall.com\/\"],\"url\":\"https:\/\/www.fibermall.com\/blog.htm?author=4\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging - fibermall.com","description":"Many CPO modules produced using the CPO process use FA-type patch cords for internal fiber routing and pluggable connections.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm","og_locale":"en_US","og_type":"article","og_title":"Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging","og_description":"With the surge in demand for computational power driven by AI technologies, major manufacturers are developing new high-speed optical module products to","og_url":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm","og_site_name":"fibermall.com","article_published_time":"2024-07-03T08:32:55+00:00","article_modified_time":"2024-07-03T08:33:04+00:00","og_image":[{"width":692,"height":453,"url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png","type":"image\/png"}],"author":"Mia","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Mia","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#article","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm"},"author":{"name":"Mia","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/56a37c7b0e1e8c61823cd6ef48e8dce3"},"headline":"Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging","datePublished":"2024-07-03T08:32:55+00:00","dateModified":"2024-07-03T08:33:04+00:00","mainEntityOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm"},"wordCount":554,"commentCount":0,"publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png","articleSection":["Blog","Fiber Optic Transceivers"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm","url":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm","name":"Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging - fibermall.com","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#primaryimage"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png","datePublished":"2024-07-03T08:32:55+00:00","dateModified":"2024-07-03T08:33:04+00:00","description":"Many CPO modules produced using the CPO process use FA-type patch cords for internal fiber routing and pluggable connections.","breadcrumb":{"@id":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#primaryimage","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Senkos-CPO-module-internal-schematic-using-board-to-board-connectors.png","width":692,"height":453,"caption":"Senkos-CPO-module-internal-schematic-using-board-to-board-connectors"},{"@type":"BreadcrumbList","@id":"https:\/\/www.fibermall.com\/blog\/cpo-for-fiber-interconnect.htm#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fibermall.com\/blog.htm"},{"@type":"ListItem","position":2,"name":"Co-Packaged Optics (CPO) Solutions for Fiber Interconnect in Module Packaging"}]},{"@type":"WebSite","@id":"https:\/\/www.fibermall.com\/blog.htm\/#website","url":"https:\/\/www.fibermall.com\/blog.htm\/","name":"fibermall.com","description":"Optical Communication Expert","publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization","name":"fibermall.com","url":"https:\/\/www.fibermall.com\/blog.htm\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","width":200,"height":67,"caption":"fibermall.com"},"image":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/56a37c7b0e1e8c61823cd6ef48e8dce3","name":"Mia","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/2e83831e57346d5d451c45e43aa96d14fc758d8f72f7304810e123b36585382b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2e83831e57346d5d451c45e43aa96d14fc758d8f72f7304810e123b36585382b?s=96&d=mm&r=g","caption":"Mia"},"description":"Optical Transmission Consultant","sameAs":["https:\/\/www.fibermall.com\/"],"url":"https:\/\/www.fibermall.com\/blog.htm?author=4"}]}},"_links":{"self":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/10039","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10039"}],"version-history":[{"count":4,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/10039\/revisions"}],"predecessor-version":[{"id":10063,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/10039\/revisions\/10063"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/media\/10048"}],"wp:attachment":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10039"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=10039"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=10039"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}