{"id":10136,"date":"2024-07-08T06:18:21","date_gmt":"2024-07-08T06:18:21","guid":{"rendered":"https:\/\/www.fibermall.com\/blog\/?p=10136"},"modified":"2026-09-11T07:07:12","modified_gmt":"2026-09-11T07:07:12","slug":"everything-you-need-to-know-about-nvidia-nvlink-compatible-cards-from-rtx-3090-to-geforce-rtx-30-series-graphics","status":"publish","type":"post","link":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm","title":{"rendered":"NVLink Compatible Cards: Every GPU and the Cables It Needs"},"content":{"rendered":"\n<p>NVLink compatible cards are the GPUs that can share memory and move data directly over NVIDIA&#8217;s high-speed interconnect, and in 2026 that list splits into two very different groups. Consumer GeForce support ended with the RTX 3090 in 2020. The RTX 40-series and RTX 50-series have no NVLink connector at all. Everything since has moved to the data center, where A100, H100, H200, B200, GB200, and GB300 cards use NVLink 3, 4, and 5 to build GPU domains of 72 accelerators or more. The Vera Rubin generation extends that to NVLink 6 in the second half of 2026.<\/p>\n\n\n\n<p>That split matters when you buy hardware or cabling. A card&#8217;s NVLink generation sets its bandwidth, and the generation also decides whether the fabric runs on copper inside the rack or on optical links between racks. This guide lists every NVLink compatible card by generation, explains why NVIDIA dropped the connector on GeForce, and maps each category to the DAC cables, active electrical cables, MPO trunks, and OSFP optics that carry its traffic.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#What_Are_NVLink_Compatible_Cards\" >What Are NVLink Compatible Cards?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#NVLink_NVSwitch_and_the_Two_Kinds_of_Compatibility\" >NVLink, NVSwitch, and the Two Kinds of Compatibility<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#How_NVLink_Compatibility_Differs_From_SLI\" >How NVLink Compatibility Differs From SLI<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Why_Bridge_Slots_Matter_on_Legacy_Cards\" >Why Bridge Slots Matter on Legacy Cards<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#NVLink_Compatible_Cards_The_Complete_2026_List\" >NVLink Compatible Cards: The Complete 2026 List<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Consumer_GeForce_and_TITAN_Cards_With_NVLink\" >Consumer GeForce and TITAN Cards With NVLink<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Workstation_Cards_RTX_A-Series_and_RTX_PRO_Blackwell\" >Workstation Cards: RTX A-Series and RTX PRO Blackwell<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Data-Center_Cards_A100_H100_B200_GB200_and_GB300\" >Data-Center Cards: A100, H100, B200, GB200, and GB300<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#The_2026_Flagship_Vera_Rubin_and_NVLink_6\" >The 2026 Flagship: Vera Rubin and NVLink 6<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Why_NVIDIA_Dropped_NVLink_on_GeForce_After_the_RTX_3090\" >Why NVIDIA Dropped NVLink on GeForce After the RTX 3090<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#What_the_RTX_40-Series_and_RTX_50-Series_Changed\" >What the RTX 40-Series and RTX 50-Series Changed<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#What_This_Means_If_You_Still_Run_RTX_3090s\" >What This Means If You Still Run RTX 3090s<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#NVLink_Generations_and_Bandwidth_Which_Card_Supports_What\" >NVLink Generations and Bandwidth: Which Card Supports What<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#The_NVLink_1_to_6_Bandwidth_Table\" >The NVLink 1 to 6 Bandwidth Table<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Reading_the_Numbers_Per-GPU_Aggregate_vs_Per-Link\" >Reading the Numbers: Per-GPU Aggregate vs Per-Link<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Scale-Up_vs_Scale-Out_Where_NVLink_Ends_and_Optics_Begin\" >Scale-Up vs Scale-Out: Where NVLink Ends and Optics Begin<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Inside_the_Rack_Copper_NVLink\" >Inside the Rack: Copper NVLink<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Between_Racks_InfiniBand_NDR_and_800G_OSFP\" >Between Racks: InfiniBand NDR and 800G OSFP<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#The_Cabling_Each_NVLink_Compatible_Card_Needs\" >The Cabling Each NVLink Compatible Card Needs<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#NVLink_vs_PCIe_vs_InfiniBand_Choosing_an_Interconnect\" >NVLink vs PCIe vs InfiniBand: Choosing an Interconnect<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#When_NVLink_Is_Worth_the_Cost\" >When NVLink Is Worth the Cost<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#How_to_Choose_an_NVLink_Compatible_Card_in_2026\" >How to Choose an NVLink Compatible Card in 2026<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Frequently_Asked_Questions\" >Frequently Asked Questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#What_is_an_NVLink_compatible_card\" >What is an NVLink compatible card?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Which_NVIDIA_cards_support_NVLink\" >Which NVIDIA cards support NVLink?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Does_the_RTX_4090_or_RTX_5090_support_NVLink\" >Does the RTX 4090 or RTX 5090 support NVLink?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#What_do_I_need_to_enable_NVLink_on_an_RTX_3090\" >What do I need to enable NVLink on an RTX 3090?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#How_many_GPUs_can_NVLink_connect\" >How many GPUs can NVLink connect?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#What_is_the_difference_between_NVLink_and_SLI\" >What is the difference between NVLink and SLI?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Is_NVLink_faster_than_PCIe\" >Is NVLink faster than PCIe?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Does_NVLink_use_copper_or_fiber_optic_cables\" >Does NVLink use copper or fiber optic cables?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-32\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#What_cables_does_a_GB200_NVL72_rack_need\" >What cables does a GB200 NVL72 rack need?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-33\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Do_I_need_NVLink_for_AI_training\" >Do I need NVLink for AI training?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-34\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Are_NVLink_Compatible_Cards\"><\/span><strong>What Are NVLink Compatible Cards?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>NVLink compatible cards are NVIDIA GPUs fitted with the NVLink interconnect, which lets two or more GPUs exchange data directly instead of routing it through PCIe and host memory. Compatibility is defined by generation. A card supports the NVLink version built into its architecture, and linked cards need matching bridges or matching switch ports.<\/p>\n\n\n\n<p>NVLink exists because PCIe became a bottleneck in multi-GPU systems. With NVLink, GPUs pass data and share memory peer to peer, and the CPU, host memory, and PCIe bus drop out of the path. Across six generations the aggregate bandwidth per GPU has grown from 160 GB\/s to 3.6 TB\/s. NVIDIA&#8217;s NVLink product page&nbsp;tracks the current specifications.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/What-Are-NVLink-Compatible-Cards.png\" alt=\"What Are NVLink Compatible Cards\" class=\"wp-image-20263\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/What-Are-NVLink-Compatible-Cards.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/What-Are-NVLink-Compatible-Cards-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/What-Are-NVLink-Compatible-Cards-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"NVLink_NVSwitch_and_the_Two_Kinds_of_Compatibility\"><\/span><strong>NVLink, NVSwitch, and the Two Kinds of Compatibility<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The word &#8220;compatible&#8221; means two different things depending on the card.<\/p>\n\n\n\n<p>On consumer and workstation cards, NVLink compatibility is physical. Two matching GPUs are joined by a removable <strong>NVLink bridge<\/strong>&nbsp;that clips over the top edges of both cards. The bridge comes in 2-slot, 3-slot, and 4-slot spacings so it can span the gap between adjacent cards.<\/p>\n\n\n\n<p>On data-center cards, compatibility is fabric-based. GPUs connect through <strong>NVSwitch<\/strong>&nbsp;ASICs, which create an all-to-all fabric so any GPU can reach any other at full NVLink bandwidth. NVIDIA introduced NVSwitch with the DGX-2 in 2018, and a rack-scale domain such as the GB200 NVL72 now treats up to 72 GPUs as one large device. That is roughly 130 TB\/s of fabric bandwidth in a single cabinet.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/NVLink-NVSwitch-and-the-Two-Kinds-of-Compatibility.png\" alt=\"NVLink, NVSwitch, and the Two Kinds of Compatibility\" class=\"wp-image-20264\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/NVLink-NVSwitch-and-the-Two-Kinds-of-Compatibility.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/NVLink-NVSwitch-and-the-Two-Kinds-of-Compatibility-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/NVLink-NVSwitch-and-the-Two-Kinds-of-Compatibility-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_NVLink_Compatibility_Differs_From_SLI\"><\/span><strong>How NVLink Compatibility Differs From SLI<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>NVLink and SLI are often confused, and the confusion changes what hardware you buy. <strong>SLI<\/strong>&nbsp;(Scalable Link Interface) was a rendering technology that combined two or more GeForce cards for gaming. It used its own bridge, the SLI HB bridge on the Turing generation. <strong>NVLink<\/strong>&nbsp;is a general-purpose data interconnect for memory sharing and compute workloads.<\/p>\n\n\n\n<p>The two are not interchangeable. An RTX 3090 does not take an SLI HB bridge. It takes an NVLink bridge, in a 3-slot or 4-slot length. If you are enabling NVLink on an RTX 3090, an SLI bridge will not fit the connector and will not work.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_Bridge_Slots_Matter_on_Legacy_Cards\"><\/span><strong>Why Bridge Slots Matter on Legacy Cards<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Slot spacing is only relevant to the legacy GeForce cards, and it is decided by your motherboard layout rather than by the GPU. A 3-slot bridge spans a one-card gap, while a 4-slot bridge spans a wider gap left by thicker coolers or a riser. Getting this wrong is the most common reason a used RTX 3090 NVLink pair will not link, so measure the gap between the two card edges before ordering.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"NVLink_Compatible_Cards_The_Complete_2026_List\"><\/span><strong>NVLink Compatible Cards: The Complete 2026 List<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The table below is the master compatibility list. Bandwidth is bidirectional aggregate per GPU. &#8220;Discontinued&#8221; means NVIDIA no longer builds the NVLink connector into that product family, even though used cards still work.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Card<\/strong><\/td><td><strong>Architecture and year<\/strong><\/td><td><strong>NVLink gen<\/strong><\/td><td><strong>Bandwidth per GPU<\/strong><\/td><td><strong>NVLink status<\/strong><\/td><td><strong>Interconnect needed<\/strong><\/td><\/tr><tr><td>TITAN RTX, RTX 2080 Ti, RTX 2080, RTX 2080 Super<\/td><td>Turing, 2018<\/td><td>NVLink 2<\/td><td>~100 GB\/s<\/td><td>Discontinued<\/td><td>2-slot or 3-slot NVLink bridge<\/td><\/tr><tr><td>RTX 3090 (base model)<\/td><td>Ampere, 2020<\/td><td>NVLink 3<\/td><td>112.5 GB\/s<\/td><td>Discontinued, last GeForce<\/td><td>3-slot or 4-slot NVLink bridge<\/td><\/tr><tr><td>RTX A5000, RTX A6000<\/td><td>Ampere pro, 2021<\/td><td>NVLink 3<\/td><td>~112.5 GB\/s<\/td><td>End of line<\/td><td>2-slot NVLink bridge<\/td><\/tr><tr><td>RTX PRO 6000 Blackwell<\/td><td>Blackwell, 2025<\/td><td>NVLink 5<\/td><td>~1.8 TB\/s<\/td><td>Current<\/td><td>NVLink 5 link between paired cards<\/td><\/tr><tr><td>A100<\/td><td>Ampere, 2020<\/td><td>NVLink 3<\/td><td>600 GB\/s<\/td><td>Legacy<\/td><td>NVSwitch fabric on copper<\/td><\/tr><tr><td>H100, H200<\/td><td>Hopper, 2022 to 2024<\/td><td>NVLink 4<\/td><td>900 GB\/s<\/td><td>Current<\/td><td>NVSwitch 3; 1.6T OSFP between racks<\/td><\/tr><tr><td>B200, GB200, GB300<\/td><td>Blackwell, 2024 to 2026<\/td><td>NVLink 5<\/td><td>1.8 TB\/s<\/td><td>Current<\/td><td>NVSwitch 4; copper in rack, 800G and 1.6T optics between racks<\/td><\/tr><tr><td>Vera Rubin<\/td><td>Rubin, 2026<\/td><td>NVLink 6<\/td><td>3.6 TB\/s<\/td><td>Shipping 2H 2026<\/td><td>NVLink 6 fabric; co-packaged optics on the roadmap<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Consumer_GeForce_and_TITAN_Cards_With_NVLink\"><\/span><strong>Consumer GeForce and TITAN Cards With NVLink<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Four NVLink compatible cards came from the Turing generation: the TITAN RTX, the RTX 2080 Ti, the RTX 2080, and the RTX 2080 Super. Each links to one partner card over a bridge at roughly 100 GB\/s. The RTX 2070 Super is often listed as NVLink capable, but it has no NVLink connector and never did.<\/p>\n\n\n\n<p>The Ampere generation narrowed that to a single card. The <strong>RTX 3090 (base model)<\/strong>&nbsp;is the last consumer GeForce GPU with an NVLink connector, offering 112.5 GB\/s between two cards. The RTX 3090 Ti shipped with the physical connector but NVIDIA disabled NVLink support in the drivers, so treat the base RTX 3090 as the practical end of the line.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Workstation_Cards_RTX_A-Series_and_RTX_PRO_Blackwell\"><\/span><strong>Workstation Cards: RTX A-Series and RTX PRO Blackwell<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Professional Ampere cards kept NVLink after GeForce dropped it. The RTX A5000 and RTX A6000 both link over a 2-slot bridge at about 112.5 GB\/s, and both are correctly classed as professional Ampere cards rather than GeForce 30-series parts.<\/p>\n\n\n\n<p>The line resumed with the <strong>RTX PRO 6000 Blackwell<\/strong>, which brings NVLink 5 to a workstation card at roughly 1.8 TB\/s. For studios and labs, this is the only current-generation way to buy NVLink on a single-slot-class card rather than in a server.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Data-Center_Cards_A100_H100_B200_GB200_and_GB300\"><\/span><strong>Data-Center Cards: A100, H100, B200, GB200, and GB300<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The data-center line is where NVLink compatible cards perform at full specification. These cards do not use bridges; they attach to a switch fabric.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>A100 (Ampere, 2020)<\/strong>\u00a0uses NVLink 3 at 600 GB\/s per GPU across 12 links, connected by second-generation NVSwitch into 8-GPU domains.<\/li>\n\n\n\n<li><strong>H100 and H200 (Hopper)<\/strong>\u00a0use NVLink 4 at 900 GB\/s per GPU across 18 links. Third-generation NVSwitch adds in-network reduction, and external NVLink Switch modules extend a domain to 256 GPUs.<\/li>\n\n\n\n<li><strong>B200, GB200, and GB300 (Blackwell)<\/strong>\u00a0use NVLink 5 at 1.8 TB\/s per GPU. A GB200 NVL72 rack connects 72 GPUs through nine NVSwitch trays as one domain, and GB300 Blackwell Ultra is the volume platform through 2026.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/The-2026-Flagship-Vera-Rubin-and-NVLink-6.png\" alt=\"The 2026 Flagship Vera Rubin and NVLink 6\" class=\"wp-image-20265\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/The-2026-Flagship-Vera-Rubin-and-NVLink-6.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/The-2026-Flagship-Vera-Rubin-and-NVLink-6-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/The-2026-Flagship-Vera-Rubin-and-NVLink-6-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"The_2026_Flagship_Vera_Rubin_and_NVLink_6\"><\/span><strong>The 2026 Flagship: Vera Rubin and NVLink 6<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Vera Rubin brings NVLink 6, which doubles per-GPU bandwidth again to 3.6 TB\/s across as many as 36 links. The first system, Vera Rubin NVL144, is scheduled to ship in the second half of 2026, and Rubin Ultra adds co-packaged optics to the roadmap. For anyone buying cabling, this is the transition to watch, because NVLink 6 shifts more of the fabric onto high-speed optical and active electrical links. NVIDIA&#8217;s NVLink Fusion program&nbsp;opens the fabric to partner silicon and carries it further over optics, which is why the 1.6T OSFP layer matters for future deployments. Our companion guide on NVLink and NVSwitch generations and topology&nbsp;covers the switch fabric history in depth.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_NVIDIA_Dropped_NVLink_on_GeForce_After_the_RTX_3090\"><\/span><strong>Why NVIDIA Dropped NVLink on GeForce After the RTX 3090<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The single most useful fact about NVLink compatible cards in 2026 is this: <strong>NVIDIA removed NVLink from consumer GeForce cards after the RTX 3090.<\/strong>&nbsp;The RTX 40-series (Ada, 2022) and the RTX 50-series (Blackwell, 2025) have no NVLink connector.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_the_RTX_40-Series_and_RTX_50-Series_Changed\"><\/span><strong>What the RTX 40-Series and RTX 50-Series Changed<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>NVIDIA reclaimed the die area and board space that NVLink consumed and spent it on Tensor Cores, DLSS hardware, and higher clocks instead. The calculation was simple. Very few GeForce buyers ran two cards in a shared-memory configuration, while every buyer benefits from more compute and better rasterization. NVLink survived only where memory sharing drives the workload: professional, workstation, and data-center silicon.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_This_Means_If_You_Still_Run_RTX_3090s\"><\/span><strong>What This Means If You Still Run RTX 3090s<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The RTX 3090 remains a legitimate NVLink card for local AI work in 2026, and it is the last consumer option for a bridged pair. Two RTX 3090s joined by an NVLink bridge expose 48 GB of combined framebuffer, which is enough to hold models that a single 24 GB card cannot. Software support is mature, and tensor parallelism in DeepSpeed and vLLM can split a model across the pair.<\/p>\n\n\n\n<p>If you are building this kind of system, plan the bridge and the intervening cabling together. A 3-slot or 4-slot NVLink bridge is a hard requirement, and the bridge only carries the 112.5 GB\/s link. Storage, host traffic, and any multi-node work still travel over PCIe or Ethernet.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"NVLink_Generations_and_Bandwidth_Which_Card_Supports_What\"><\/span><strong>NVLink Generations and Bandwidth: Which Card Supports What<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Every NVLink compatible card belongs to a generation, and that generation sets its bandwidth ceiling. The generation is fixed by architecture rather than by configuration. NVIDIA has revised the NVLink specification&nbsp;six times since 2016, each time roughly doubling the per-GPU rate. The table below condenses all six.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"The_NVLink_1_to_6_Bandwidth_Table\"><\/span><strong>The NVLink 1 to 6 Bandwidth Table<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Generation<\/strong><\/td><td><strong>Year<\/strong><\/td><td><strong>First GPU<\/strong><\/td><td><strong>Links per GPU<\/strong><\/td><td><strong>Bandwidth per GPU<\/strong><\/td><\/tr><tr><td>NVLink 1<\/td><td>2016<\/td><td>Tesla P100 (Pascal)<\/td><td>4<\/td><td>160 GB\/s<\/td><\/tr><tr><td>NVLink 2<\/td><td>2017<\/td><td>Tesla V100 (Volta)<\/td><td>6<\/td><td>300 GB\/s<\/td><\/tr><tr><td>NVLink 3<\/td><td>2020<\/td><td>A100 (Ampere)<\/td><td>12<\/td><td>600 GB\/s<\/td><\/tr><tr><td>NVLink 4<\/td><td>2022<\/td><td>H100 (Hopper)<\/td><td>18<\/td><td>900 GB\/s<\/td><\/tr><tr><td>NVLink 5<\/td><td>2024<\/td><td>B200 (Blackwell)<\/td><td>18<\/td><td>1.8 TB\/s<\/td><\/tr><tr><td>NVLink 6<\/td><td>2026<\/td><td>Vera Rubin<\/td><td>up to 36<\/td><td>3.6 TB\/s<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/NVLink-Generations-and-Bandwidth.png\" alt=\"NVLink Generations and Bandwidth\" class=\"wp-image-20266\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/NVLink-Generations-and-Bandwidth.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/NVLink-Generations-and-Bandwidth-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/NVLink-Generations-and-Bandwidth-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Reading_the_Numbers_Per-GPU_Aggregate_vs_Per-Link\"><\/span><strong>Reading the Numbers: Per-GPU Aggregate vs Per-Link<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Two details prevent most misreading of NVLink specs.<\/p>\n\n\n\n<p>First, published bandwidth is <strong>bidirectional aggregate<\/strong>, meaning transmit plus receive. A figure of 900 GB\/s on an H100 is 450 GB\/s in each direction, not 900 GB\/s each way.<\/p>\n\n\n\n<p>Second, a card can share a generation without sharing the bandwidth. The RTX 3090 and the A100 both use NVLink 3, yet the RTX 3090 delivers 112.5 GB\/s while the A100 delivers 600 GB\/s. The consumer card devotes one link pair to the bridge, while the data-center card puts 12 links on a switch fabric. Never assume two cards with the same generation number perform alike.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Scale-Up_vs_Scale-Out_Where_NVLink_Ends_and_Optics_Begin\"><\/span><strong>Scale-Up vs Scale-Out: Where NVLink Ends and Optics Begin<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Every NVIDIA AI cluster has two networks, and they use different physical media. The two layers also decide what kind of transceiver, DAC, or copper assembly a given NVLink compatible card needs. Getting the boundary right is the difference between a working fabric and a rack of dropped links.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Inside_the_Rack_Copper_NVLink\"><\/span><strong>Inside the Rack: Copper NVLink<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p><strong>Scale-up<\/strong>&nbsp;is NVLink, and inside a rack it runs on copper. A GB200 NVL72 uses copper NVLink at the rear of the cabinet because the distances are short, under a few meters, and the power saving is large. Running that fabric optically would add roughly 20 kW per rack. Those copper runs are high-speed twin-axial assemblies, effectively large DAC cables, that plug into the compute trays and the NVSwitch trays.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Between_Racks_InfiniBand_NDR_and_800G_OSFP\"><\/span><strong>Between Racks: InfiniBand NDR and 800G OSFP<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p><strong>Scale-out<\/strong>&nbsp;is the network that carries jobs, storage, and traffic between racks, and it runs on optics. DGX H100 systems use 400G ConnectX-7 InfiniBand, GB300 moves to 800G ConnectX-8, and the switches are Quantum-X800 for InfiniBand or Spectrum-X800 for Ethernet. Where an NVLink domain must cross a rack boundary, as in the two-cabinet GB200 NVL36x2, the NVSwitch trays connect through 1.6T OSFP cages carrying real NVLink traffic.<\/p>\n\n\n\n<p>The practical rule is simple. Keep NVLink on copper where the distance is short and the power budget is tight, switch to optics where reach or density demands it, and standardize on 800G and 1.6T OSFP so the cabling carries across the GB300 and Vera Rubin generations.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Scale-Up-vs-Scale-Out.png\" alt=\"Scale-Up vs Scale-Out\" class=\"wp-image-20267\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Scale-Up-vs-Scale-Out.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Scale-Up-vs-Scale-Out-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/Scale-Up-vs-Scale-Out-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"The_Cabling_Each_NVLink_Compatible_Card_Needs\"><\/span><strong>The Cabling Each NVLink Compatible Card Needs<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>This table maps the compatibility list to the physical layer, which is the part a cabling supplier can actually help with.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>NVLink domain<\/strong><\/td><td><strong>Typical link<\/strong><\/td><td><strong>Recommended connectivity<\/strong><\/td><\/tr><tr><td>GeForce RTX 3090 pair<\/td><td>NVLink 3 bridge<\/td><td>3-slot or 4-slot NVLink bridge (legacy)<\/td><\/tr><tr><td>Workstation pair (A6000, RTX PRO 6000)<\/td><td>NVLink bridge or link<\/td><td>2-slot NVLink bridge, or NVLink 5 link<\/td><\/tr><tr><td>8-GPU node (A100, H100)<\/td><td>Copper NVLink on NVSwitch<\/td><td>High-speed DAC and copper backplane runs<\/td><\/tr><tr><td>Rack-scale domain (GB200, GB300 NVL72)<\/td><td>Copper NVLink in rack<\/td><td>Short twin-ax DAC assemblies inside the cabinet<\/td><\/tr><tr><td>Rack-to-rack NVLink (NVL36x2)<\/td><td>1.6T OSFP cages<\/td><td>800G OSFP optics or 1.6T active electrical cables<\/td><\/tr><tr><td>External NVLink domain<\/td><td>OSFP plus fiber<\/td><td>OSFP optical transceivers and MPO fiber trunks<\/td><\/tr><tr><td>Scale-out InfiniBand (GB300)<\/td><td>800G ConnectX-8<\/td><td>800G OSFP SR8 or DR8 modules, NDR DAC<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>FiberMall builds NVIDIA-compatible modules for every link in that table. On the optical side, the <a href=\"https:\/\/www.fibermall.com\/sale-460315-nvidia-mma4z00-ns.htm\" target=\"_blank\" rel=\"noreferrer noopener\">800G OSFP SR8 module<\/a>\u00a0serves short-reach scale-out and NVLink fabrics, while 800G NDR DAC cables\u00a0handle the short copper hops inside a rack.<\/p>\n\n\n\n<p>The rest of the lineup maps directly onto the fabric layers:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>twin-port OSFP breakout DACs\u00a0for rack-to-rack NVLink pairs<\/li>\n\n\n\n<li>MPO fiber trunks\u00a0for external NVLink domains<\/li>\n\n\n\n<li>1.6T OSFP modules\u00a0for the transition to Vera Rubin<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"NVLink_vs_PCIe_vs_InfiniBand_Choosing_an_Interconnect\"><\/span><strong>NVLink vs PCIe vs InfiniBand: Choosing an Interconnect<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Buyers often weigh three options, and they solve different problems. The comparison below uses bidirectional numbers.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Interconnect<\/strong><\/td><td><strong>Typical peak bandwidth<\/strong><\/td><td><strong>Role<\/strong><\/td><\/tr><tr><td>PCIe 5.0 x16<\/td><td>~128 GB\/s per slot<\/td><td>General I\/O, host to GPU<\/td><\/tr><tr><td>PCIe 6.0 x16<\/td><td>~256 GB\/s per slot<\/td><td>Next-generation I\/O<\/td><\/tr><tr><td>NVLink 3 (A100)<\/td><td>600 GB\/s per GPU<\/td><td>Scale-up within a node<\/td><\/tr><tr><td>NVLink 4 (H100)<\/td><td>900 GB\/s per GPU<\/td><td>Scale-up within a node<\/td><\/tr><tr><td>NVLink 5 (B200)<\/td><td>1.8 TB\/s per GPU<\/td><td>Scale-up within a rack<\/td><\/tr><tr><td>NVLink 6 (Rubin)<\/td><td>3.6 TB\/s per GPU<\/td><td>Scale-up across racks<\/td><\/tr><tr><td>InfiniBand NDR (400G)<\/td><td>~50 GB\/s per port<\/td><td>Scale-out between racks<\/td><\/tr><tr><td>800G Ethernet<\/td><td>~100 GB\/s per port<\/td><td>Scale-out between racks<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"When_NVLink_Is_Worth_the_Cost\"><\/span><strong>When NVLink Is Worth the Cost<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>NVLink wins whenever GPUs must exchange data every step, which describes tensor parallelism, mixture-of-experts routing, and large-model training. NVLink compatible cards cost more than PCIe-only alternatives, so the interconnect has to earn its place. An NVLink domain moves that traffic more than an order of magnitude faster than PCIe, and it does so with coherent memory semantics that remove a layer of software message passing.<\/p>\n\n\n\n<p>InfiniBand and Ethernet remain essential, but they serve a different purpose. They scale a cluster to hundreds of nodes, which NVLink does not do on its own. Plan for both, and size the optical layer for the scale-out traffic rather than for the NVLink fabric.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_to_Choose_an_NVLink_Compatible_Card_in_2026\"><\/span><strong>How to Choose an NVLink Compatible Card in 2026<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Work through these steps in order. The card choice determines every cabling decision that follows.<\/p>\n\n\n\n<p>1. <strong>Decide whether you need NVLink at all.<\/strong>&nbsp;For single-GPU inference, PCIe is enough. NVLink pays off when a model or workload must be split across GPUs that exchange data constantly.<\/p>\n\n\n\n<p>2. <strong>Match the generation to the workload.<\/strong>&nbsp;A legacy RTX 3090 pair covers local fine-tuning and small model serving. A100 and H100 cover mainstream training. B200, GB200, and GB300 cover frontier training and large-scale serving.<\/p>\n\n\n\n<p>3. <strong>Confirm the connector still exists.<\/strong>&nbsp;If you are buying GeForce, only the RTX 3090 has NVLink. RTX 40-series and 50-series cards cannot be linked.<\/p>\n\n\n\n<p>4. <strong>Size the bridge or the fabric.<\/strong>&nbsp;Bridged pairs need the correct slot length. Switch-based systems need NVSwitch trays and the right number of them for the domain size.<\/p>\n\n\n\n<p>5. <strong>Plan the physical layer.<\/strong>\u00a0Choose copper DAC for in-rack NVLink, 800G or 1.6T OSFP optics for rack-to-rack NVLink, and <a href=\"https:\/\/www.fibermall.com\/store-21994-800g-ndr-infiniband.htm\" target=\"_blank\" rel=\"noreferrer noopener\">NDR or 800G modules<\/a> for the scale-out network.<\/p>\n\n\n\n<p>6. <strong>Standardize on 800G and 1.6T OSFP.<\/strong>&nbsp;Reaching for the forward-looking optic now avoids a re-cable when GB300 and Vera Rubin systems arrive.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span><strong>Frequently Asked Questions<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_is_an_NVLink_compatible_card\"><\/span><strong>What is an NVLink compatible card?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>An NVLink compatible card is an NVIDIA GPU with a built-in NVLink interconnect, which lets it share memory and exchange data directly with another GPU at far higher bandwidth than PCIe allows. Consumer cards link over a physical bridge, while data-center cards link through NVSwitch fabrics.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Which_NVIDIA_cards_support_NVLink\"><\/span><strong>Which NVIDIA cards support NVLink?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The NVLink compatible cards available in 2026 are the RTX PRO 6000 Blackwell workstation card, the A100, H100, H200, B200, GB200, and GB300 data-center GPUs, and the incoming Vera Rubin generation. On the consumer side, only legacy Turing and Ampere cards qualify, ending with the RTX 3090.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Does_the_RTX_4090_or_RTX_5090_support_NVLink\"><\/span><strong>Does the RTX 4090 or RTX 5090 support NVLink?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>No. NVIDIA removed NVLink from GeForce with the RTX 40-series in 2022, and the RTX 50-series also ships without the connector. The RTX 3090, released in 2020, is the last consumer GeForce card with NVLink support.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_do_I_need_to_enable_NVLink_on_an_RTX_3090\"><\/span><strong>What do I need to enable NVLink on an RTX 3090?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>You need two RTX 3090 cards and one NVLink bridge in the correct slot length, either 3-slot or 4-slot depending on the gap between the cards. An SLI HB bridge will not work. The bridge only provides the 112.5 GB\/s link; other traffic still uses PCIe.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_many_GPUs_can_NVLink_connect\"><\/span><strong>How many GPUs can NVLink connect?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Two bridged consumer or workstation cards is the practical consumer limit. On data-center systems, NVSwitch scales the domain from 8 GPUs to a 72-GPU NVL72 rack, and external NVLink switches extend Hopper-generation domains to 256 GPUs.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_NVLink_and_SLI\"><\/span><strong>What is the difference between NVLink and SLI?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>NVLink is a general-purpose interconnect for memory sharing and compute workloads. SLI was a rendering technology that combined GeForce cards for gaming. They use different bridges, and an SLI bridge cannot be used to enable NVLink on an RTX 3090.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Is_NVLink_faster_than_PCIe\"><\/span><strong>Is NVLink faster than PCIe?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Yes, by a wide margin. NVLink 5 delivers 1.8 TB\/s per GPU against roughly 128 GB\/s for a PCIe 5.0 x16 slot, which is about 14 times the bandwidth. NVLink also bypasses the CPU and host memory for GPU-to-GPU traffic.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Does_NVLink_use_copper_or_fiber_optic_cables\"><\/span><strong>Does NVLink use copper or fiber optic cables?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Both. NVLink runs on copper inside a rack, as in the GB200 NVL72, where copper saves roughly 20 kW per cabinet. It crosses racks through 1.6T OSFP optical modules and active electrical cables, and NVIDIA&#8217;s NVLink Fusion roadmap extends NVLink further over optics.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_cables_does_a_GB200_NVL72_rack_need\"><\/span><strong>What cables does a GB200 NVL72 rack need?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>An NVL72 rack needs short high-speed copper NVLink assemblies between its compute trays and NVSwitch trays, plus 800G OSFP optics and DAC or AEC cables for rack-to-rack and scale-out links. FiberMall carries NVIDIA-compatible options across each of these categories.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Do_I_need_NVLink_for_AI_training\"><\/span><strong>Do I need NVLink for AI training?<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>It depends on model size. Single-GPU training works over PCIe. Once a model must be split across GPUs that exchange gradients every step, NVLink becomes the practical requirement, which is why every major training cluster is built around NVLink domains and NVSwitch.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span><strong>Conclusion<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>NVLink compatible cards now describe two markets that were once one. The consumer era ended at the RTX 3090, which remains the last GeForce card with an NVLink connector and still has a role in local AI work. Everything current lives in the data center, where NVLink 4 and NVLink 5 turn a rack into a single 72-GPU accelerator, and NVLink 6 will extend that reach again in late 2026.<\/p>\n\n\n\n<p>The takeaways for anyone specifying hardware or cabling:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Consumer NVLink compatibility starts and stops with legacy Turing and Ampere cards, ending at the RTX 3090.<\/li>\n\n\n\n<li>Current NVLink compatible cards are the RTX PRO 6000 Blackwell and the A100, H100, H200, B200, GB200, and GB300 data-center GPUs.<\/li>\n\n\n\n<li>Bandwidth is tied to generation, but a shared generation number does not mean shared bandwidth. The RTX 3090 and A100 both use NVLink 3, yet one delivers 112.5 GB\/s and the other 600 GB\/s.<\/li>\n\n\n\n<li>Scale-up NVLink stays on copper inside the rack, while scale-out traffic and rack-to-rack NVLink run on 800G and 1.6T OSFP optics.<\/li>\n\n\n\n<li>Standardizing on 800G and 1.6T OSFP now protects your cabling investment through GB300 and into Vera Rubin.<\/li>\n<\/ul>\n\n\n\n<p>If you are sourcing the connectivity layer for an NVIDIA GPU cluster, start with FiberMall&#8217;s 800G OSFP DR8 modules and cables&nbsp;for the optical side. To match modules to your switches, network cards, and NVLink fabric, ask our engineers on the FiberMall questions page.<\/p>\n\n\n\n<p><\/p>\n<style>\r\n\r\n        .lwrp.link-whisper-related-posts{\r\n            \r\n            margin-top: 40px;\nmargin-bottom: 30px;\r\n        }\r\n        .lwrp .lwrp-title{\r\n            \r\n            \r\n        }\r\n        .lwrp .lwrp-description{\r\n            \r\n            \r\n\r\n        }\r\n        .lwrp .lwrp-list-container{\r\n        }\r\n        .lwrp .lwrp-list-multi-container{\r\n            display: flex;\r\n        }\r\n        .lwrp .lwrp-list-double{\r\n            width: 48%;\r\n        }\r\n        .lwrp .lwrp-list-triple{\r\n            width: 32%;\r\n        }\r\n        .lwrp .lwrp-list-row-container{\r\n            display: flex;\r\n            justify-content: space-between;\r\n        }\r\n        .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n            width: calc(100% - 20px);\r\n        }\r\n        .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n            \r\n            list-style: decimal;\r\n        }\r\n        .lwrp .lwrp-list-item img{\r\n            max-width: 100%;\r\n            height: auto;\r\n        }\r\n        .lwrp .lwrp-list-item.lwrp-empty-list-item{\r\n            background: initial !important;\r\n        }\r\n        .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n        .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n            \r\n                \r\n        }\r\n        @media screen and (max-width: 480px) {\r\n            .lwrp.link-whisper-related-posts{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-title{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-description{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-multi-container{\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-multi-container ul.lwrp-list{\r\n                margin-top: 0px;\r\n                margin-bottom: 0px;\r\n                padding-top: 0px;\r\n                padding-bottom: 0px;\r\n            }\r\n            .lwrp .lwrp-list-double,\r\n            .lwrp .lwrp-list-triple{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-row-container{\r\n                justify-content: initial;\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n            .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n                \r\n                    \r\n            }\r\n        }<\/style>\r\n<div id=\"link-whisper-related-posts-widget\" class=\"link-whisper-related-posts lwrp\">\r\n            <h3 class=\"lwrp-title\">Related Posts<\/h3>    \r\n        <div class=\"lwrp-list-container\">\r\n                                            <ul class=\"lwrp-list lwrp-list-single\">\r\n                    <li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/arista-cable.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Everything You Need to Know About Arista Networks&#8217; Compatible Cable Solutions<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/questions\/difference-between-400g-bidi-srbd.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">What is the Difference Between 400G-BIDI, 400G-SRBD and 400G-SR4.2?<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/mmf-vs-smf.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">The Ultimate Guide to Understanding Fiber Optic Cable Types: Single Mode vs Multimode Fiber<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/video\/the-use-of-sfp-10g-lr.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Design, construction and use of SFP 10G LR<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/how-many-optical-transceivers-does-chatgpt-require.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">How Many Optical Transceivers Does ChatGPT Require?<\/span><\/a><\/li>                <\/ul>\r\n                        <\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"<p>NVLink compatible cards are the GPUs that can share memory and move data directly over NVIDIA&#8217;s high-speed interconnect, and in 2026 that list splits into two very different groups. Consumer GeForce support ended with the RTX 3090 in 2020. The RTX 40-series and RTX 50-series have no NVLink connector at all. Everything since has moved [&hellip;]<\/p>\n","protected":false},"author":227,"featured_media":20268,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":"","_wpscppro_dont_share_socialmedia":false,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"default","_instagram_share_type":"default","_medium_share_type":"default","_threads_share_type":"default","_google_business_share_type":"default","_selected_social_profile":[{"id":"skM9ewvR8O","platform":"linkedin","platformKey":0,"name":"Jason Xue","type":"person","thumbnail_url":"https:\/\/media.licdn.com\/dms\/image\/C5603AQErPqKD0j6qBg\/profile-displayphoto-shrink_100_100\/0\/1599138392315?e=1723075200&v=beta&t=joEkh1OeKQ0F-QpAPv4xxQyBdGlHyccIQZauRSs6RvU","share_type":"default"}],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[2],"tags":[],"class_list":["post-10136","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v20.13 (Yoast SEO v25.8) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>NVLink Compatible Cards (2026): GPUs and Cables Guide<\/title>\n<meta name=\"description\" content=\"NVLink compatible cards explained: which GPUs support NVLink in 2026, why GeForce stopped at the RTX 3090, and the cables each card and cluster needs.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NVLink Compatible Cards: Every GPU and the Cables It Needs\" \/>\n<meta property=\"og:description\" content=\"NVLink compatible cards are the GPUs that can share memory and move data directly over NVIDIA&#039;s high-speed interconnect, and in 2026 that list splits into\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\" \/>\n<meta property=\"og:site_name\" content=\"fibermall.com\" \/>\n<meta property=\"article:published_time\" content=\"2024-07-08T06:18:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-11T07:07:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/nvlink-gpu.png\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Catherine\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Catherine\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"16 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\"},\"author\":{\"name\":\"Catherine\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d\"},\"headline\":\"NVLink Compatible Cards: Every GPU and the Cables It Needs\",\"datePublished\":\"2024-07-08T06:18:21+00:00\",\"dateModified\":\"2026-09-11T07:07:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\"},\"wordCount\":3235,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/nvlink-gpu.png\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\",\"url\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\",\"name\":\"NVLink Compatible Cards (2026): GPUs and Cables Guide\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/nvlink-gpu.png\",\"datePublished\":\"2024-07-08T06:18:21+00:00\",\"dateModified\":\"2026-09-11T07:07:12+00:00\",\"description\":\"NVLink compatible cards explained: which GPUs support NVLink in 2026, why GeForce stopped at the RTX 3090, and the cables each card and cluster needs.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#primaryimage\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/nvlink-gpu.png\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/nvlink-gpu.png\",\"width\":900,\"height\":600,\"caption\":\"nvlink gpu\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.fibermall.com\/blog.htm\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"NVLink Compatible Cards: Every GPU and the Cables It Needs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"name\":\"fibermall.com\",\"description\":\"Optical Communication Expert\",\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\",\"name\":\"fibermall.com\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"width\":200,\"height\":67,\"caption\":\"fibermall.com\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d\",\"name\":\"Catherine\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g\",\"caption\":\"Catherine\"},\"description\":\"Optical Communications Engineer\",\"sameAs\":[\"https:\/\/www.fibermall.com\/\"],\"url\":\"https:\/\/www.fibermall.com\/blog.htm?author=227\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NVLink Compatible Cards (2026): GPUs and Cables Guide","description":"NVLink compatible cards explained: which GPUs support NVLink in 2026, why GeForce stopped at the RTX 3090, and the cables each card and cluster needs.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm","og_locale":"en_US","og_type":"article","og_title":"NVLink Compatible Cards: Every GPU and the Cables It Needs","og_description":"NVLink compatible cards are the GPUs that can share memory and move data directly over NVIDIA's high-speed interconnect, and in 2026 that list splits into","og_url":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm","og_site_name":"fibermall.com","article_published_time":"2024-07-08T06:18:21+00:00","article_modified_time":"2026-09-11T07:07:12+00:00","og_image":[{"width":900,"height":600,"url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/nvlink-gpu.png","type":"image\/png"}],"author":"Catherine","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Catherine","Est. reading time":"16 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#article","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm"},"author":{"name":"Catherine","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d"},"headline":"NVLink Compatible Cards: Every GPU and the Cables It Needs","datePublished":"2024-07-08T06:18:21+00:00","dateModified":"2026-09-11T07:07:12+00:00","mainEntityOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm"},"wordCount":3235,"commentCount":0,"publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/nvlink-gpu.png","articleSection":["Blog"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm","url":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm","name":"NVLink Compatible Cards (2026): GPUs and Cables Guide","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#primaryimage"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/nvlink-gpu.png","datePublished":"2024-07-08T06:18:21+00:00","dateModified":"2026-09-11T07:07:12+00:00","description":"NVLink compatible cards explained: which GPUs support NVLink in 2026, why GeForce stopped at the RTX 3090, and the cables each card and cluster needs.","breadcrumb":{"@id":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#primaryimage","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/nvlink-gpu.png","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/07\/nvlink-gpu.png","width":900,"height":600,"caption":"nvlink gpu"},{"@type":"BreadcrumbList","@id":"https:\/\/www.fibermall.com\/blog\/nvlink-compatible-cards.htm#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fibermall.com\/blog.htm"},{"@type":"ListItem","position":2,"name":"NVLink Compatible Cards: Every GPU and the Cables It Needs"}]},{"@type":"WebSite","@id":"https:\/\/www.fibermall.com\/blog.htm\/#website","url":"https:\/\/www.fibermall.com\/blog.htm\/","name":"fibermall.com","description":"Optical Communication Expert","publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization","name":"fibermall.com","url":"https:\/\/www.fibermall.com\/blog.htm\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","width":200,"height":67,"caption":"fibermall.com"},"image":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d","name":"Catherine","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g","caption":"Catherine"},"description":"Optical Communications Engineer","sameAs":["https:\/\/www.fibermall.com\/"],"url":"https:\/\/www.fibermall.com\/blog.htm?author=227"}]}},"_links":{"self":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/10136","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/users\/227"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10136"}],"version-history":[{"count":4,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/10136\/revisions"}],"predecessor-version":[{"id":20269,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/10136\/revisions\/20269"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/media\/20268"}],"wp:attachment":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10136"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=10136"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=10136"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}