{"id":16747,"date":"2025-04-01T06:37:00","date_gmt":"2025-04-01T06:37:00","guid":{"rendered":"https:\/\/www.fibermall.com\/blog\/?p=16747"},"modified":"2025-04-01T06:37:51","modified_gmt":"2025-04-01T06:37:51","slug":"active-connectors-lc-cs-sn-mpo-pc-apc","status":"publish","type":"post","link":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm","title":{"rendered":"Active Connectors: LC, CS, SN, MPO, PC, APC"},"content":{"rendered":"\n<p>Active connectors are passive optical devices frequently used in conjunction with optical module interfaces.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png\" alt=\"Active Connectors\" class=\"wp-image-16750\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png 910w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors-300x198.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors-768x508.png 768w\" sizes=\"(max-width: 910px) 100vw, 910px\" \/><\/figure>\n\n\n\n<p>These connectors, which are attached to the optical side of a module, generally adhere to standardized processes to form universally accepted physical and performance interfaces, thereby enabling interoperability among various manufacturers. Standardization, as a process, involves achieving industry consensus. Over time, newer designs may be incorporated into the standards, evolving into industry-wide interoperability norms.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/interoperability.png\" alt=\"interoperability\" class=\"wp-image-16751\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/interoperability.png 972w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/interoperability-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/interoperability-768x433.png 768w\" sizes=\"(max-width: 972px) 100vw, 972px\" \/><\/figure>\n\n\n\n<p>The purpose of such interoperability is to reduce costs across the industry by splitting the supply chain into different segments. Standardized interfaces allow products from different manufacturers to be interchangeable\u2014just like USB interfaces and mobile phone charging cables, which are common examples of standard interfaces.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Optical-designs-within-optical-modules-from-different-manufacturers.png\" alt=\"Optical designs within optical modules from different manufacturers\" class=\"wp-image-16752\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Optical-designs-within-optical-modules-from-different-manufacturers.png 965w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Optical-designs-within-optical-modules-from-different-manufacturers-300x162.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Optical-designs-within-optical-modules-from-different-manufacturers-768x414.png 768w\" sizes=\"(max-width: 965px) 100vw, 965px\" \/><\/figure>\n\n\n\n<p><strong>Common Types of Active Connectors<\/strong><strong><\/strong><\/p>\n\n\n\n<p>FC Connector &nbsp;<\/p>\n\n\n\n<p>Known as a ferrule connector, it uses a screw-like mechanism for fixation and features a sturdy metallic shell. While highly stable and suitable for many scenarios, its cost is relatively high, and it is incompatible with APC (angled physical contact). As a result, its usage in modern optical modules is minimal.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/FC-Connector-1024x576.png\" alt=\"FC Connector\" class=\"wp-image-16753\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/FC-Connector-1024x576.png 1024w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/FC-Connector-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/FC-Connector-768x432.png 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/FC-Connector.png 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>SC Connector &nbsp;<\/p>\n\n\n\n<p>Widely used in Passive Optical Network (PON) systems, the SC connector, often referred to as a subscriber connector, features a ceramic ferrule with a diameter of 2.5 mm. Its primary characteristics include a simple, large, and robust design, making it ideal for fixed network access for everyday users.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/SC-Connector.png\" alt=\"SC Connector\" class=\"wp-image-16754\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/SC-Connector.png 813w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/SC-Connector-300x224.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/SC-Connector-768x574.png 768w\" sizes=\"(max-width: 813px) 100vw, 813px\" \/><\/figure>\n\n\n\n<p>LC Connector &nbsp;<\/p>\n\n\n\n<p>Smaller in size, the LC connector is extensively utilized in data center modules and 5G base station modules.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/LC-Connector-1024x576.png\" alt=\"LC Connector\" class=\"wp-image-16755\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/LC-Connector-1024x576.png 1024w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/LC-Connector-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/LC-Connector-768x432.png 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/LC-Connector.png 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Designed originally by Bell Labs, which later became Lucent Technologies, the &#8220;L&#8221; in LC stands for Lucent. It follows a push-pull latch mechanism with a ceramic ferrule diameter of 1.25 mm. Its compact and precise design aligns well with the SFP (small form-factor pluggable) optical modules and continues to be widely used today.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/small-form-factor-pluggable.png\" alt=\"(small form-factor pluggable)\" class=\"wp-image-16756\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/small-form-factor-pluggable.png 802w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/small-form-factor-pluggable-300x227.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/small-form-factor-pluggable-768x582.png 768w\" sizes=\"(max-width: 802px) 100vw, 802px\" \/><\/figure>\n\n\n\n<p>CS Connector &nbsp;<\/p>\n\n\n\n<p>Designed for the 400G era, the CS connector maintains compatibility with LC ferrules (1.25 mm in diameter) while reducing its overall structure size by 40%. This dual-port design, developed by Senko, doubles the density of LC connectors and is primarily used in QSFP-DD and OSFP modules.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/CS-Connector.png\" alt=\"CS Connector\" class=\"wp-image-16757\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/CS-Connector.png 920w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/CS-Connector-300x198.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/CS-Connector-768x508.png 768w\" sizes=\"(max-width: 920px) 100vw, 920px\" \/><\/figure>\n\n\n\n<p>SN Connector &nbsp;<\/p>\n\n\n\n<p>Also compatible with LC&#8217;s 1.25 mm ferrules, the SN connector features an even more compact structure and is used in high-density modules such as QSFP-DD. It enables a connector density four times that of LC connectors.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/SC.png\" alt=\"SC\" class=\"wp-image-16758\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/SC.png 921w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/SC-300x198.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/SC-768x507.png 768w\" sizes=\"(max-width: 921px) 100vw, 921px\" \/><\/figure>\n\n\n\n<p>MDC Connector &nbsp;<\/p>\n\n\n\n<p>Designed by US Conec, the MDC connector mirrors SN in terms of density and supports four times the connection capacity of LC connectors.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/MDC.png\" alt=\"MDC\" class=\"wp-image-16759\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/MDC.png 849w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/MDC-300x215.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/MDC-768x550.png 768w\" sizes=\"(max-width: 849px) 100vw, 849px\" \/><\/figure>\n\n\n\n<p><strong>Optical Ferrules and Interfaces<\/strong><strong><\/strong><\/p>\n\n\n\n<p>The majority of these connectors employ ceramic ferrules, which hold capillary fibers for optical path alignment. However, surface roughness, dust, or contaminants can lead to optical reflection, impairing signal transmission.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/capillary-fibers-1024x591.png\" alt=\"capillary fibers\" class=\"wp-image-16760\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/capillary-fibers-1024x591.png 1024w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/capillary-fibers-300x173.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/capillary-fibers-768x443.png 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/capillary-fibers.png 1053w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>To mitigate this, connectors are fitted with springs to maintain optimal optical contact.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/connectors-are-fitted-with-springs.png\" alt=\"connectors are fitted with springs\" class=\"wp-image-16761\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/connectors-are-fitted-with-springs.png 943w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/connectors-are-fitted-with-springs-300x193.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/connectors-are-fitted-with-springs-768x495.png 768w\" sizes=\"(max-width: 943px) 100vw, 943px\" \/><\/figure>\n\n\n\n<p>The common end-face contact types include:<\/p>\n\n\n\n<p>PC (Physical Contact): Ensures solid fiber end-face contact to establish a connection.<\/p>\n\n\n\n<p>UPC (Ultra Physical Contact): Features a spherical ferrule end-face to reduce reflection.<\/p>\n\n\n\n<p>APC (Angled Physical Contact): Employs an 8\u00b0 angled end-face to minimize reflection by directing it away from the main optical path.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/CONNECTOR-1024x576.png\" alt=\"CONNECTOR\" class=\"wp-image-16762\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/CONNECTOR-1024x576.png 1024w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/CONNECTOR-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/CONNECTOR-768x432.png 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/CONNECTOR.png 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/PC-1024x576.png\" alt=\"PC\" class=\"wp-image-16763\" style=\"width:800px\" width=\"800\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/PC-1024x576.png 1024w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/PC-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/PC-768x432.png 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/PC.png 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Among these, APC offers the highest anti-reflection capability, followed by UPC and PC.<\/p>\n\n\n\n<p>Multi-Fiber and Emerging Connectors<\/p>\n\n\n\n<p>While single-fiber connectors house one fiber (monomode or multimode), multi-fiber connectors like <a href=\"https:\/\/www.fibermall.com\/store-17109-mtp-mpo-fiber-cables.htm\" target=\"_blank\" rel=\"noreferrer noopener\">MPO\/MTP<\/a> accommodate multiple fibers, typically used with MT ferrules. These structures range from 8 to 72 fibers, supported by advancements in non-physical contact methods such as anti-reflective coatings or built-in lenses.<\/p>\n<style>\r\n\r\n        .lwrp.link-whisper-related-posts{\r\n            \r\n            margin-top: 40px;\nmargin-bottom: 30px;\r\n        }\r\n        .lwrp .lwrp-title{\r\n            \r\n            \r\n        }\r\n        .lwrp .lwrp-description{\r\n            \r\n            \r\n\r\n        }\r\n        .lwrp .lwrp-list-container{\r\n        }\r\n        .lwrp .lwrp-list-multi-container{\r\n            display: flex;\r\n        }\r\n        .lwrp .lwrp-list-double{\r\n            width: 48%;\r\n        }\r\n        .lwrp .lwrp-list-triple{\r\n            width: 32%;\r\n        }\r\n        .lwrp .lwrp-list-row-container{\r\n            display: flex;\r\n            justify-content: space-between;\r\n        }\r\n        .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n            width: calc(100% - 20px);\r\n        }\r\n        .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n            \r\n            list-style: decimal;\r\n        }\r\n        .lwrp .lwrp-list-item img{\r\n            max-width: 100%;\r\n            height: auto;\r\n        }\r\n        .lwrp .lwrp-list-item.lwrp-empty-list-item{\r\n            background: initial !important;\r\n        }\r\n        .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n        .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n            \r\n                \r\n        }\r\n        @media screen and (max-width: 480px) {\r\n            .lwrp.link-whisper-related-posts{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-title{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-description{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-multi-container{\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-multi-container ul.lwrp-list{\r\n                margin-top: 0px;\r\n                margin-bottom: 0px;\r\n                padding-top: 0px;\r\n                padding-bottom: 0px;\r\n            }\r\n            .lwrp .lwrp-list-double,\r\n            .lwrp .lwrp-list-triple{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-row-container{\r\n                justify-content: initial;\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n            .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n                \r\n                    \r\n            }\r\n        }<\/style>\r\n<div id=\"link-whisper-related-posts-widget\" class=\"link-whisper-related-posts lwrp\">\r\n            <h3 class=\"lwrp-title\">Related Posts<\/h3>    \r\n        <div class=\"lwrp-list-container\">\r\n                                            <ul class=\"lwrp-list lwrp-list-single\">\r\n                    <li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/qsfp-breakout-cable.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Understanding QSFP Breakout Cables: A Comprehensive Guide to Breakout DACs and AOCs<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/osfp112.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Everything You Need to Know About osfp112: The Future of High-Speed Optical Transceivers<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/how-many-configurations-of-a-switch.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">How Many Configurations will a New Switch Go Through?<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/news\/ericsson-wins-75-global-5g-contracts.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Defeating Huawei, Ericsson Wins 75 Global 5G Contracts<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/l2-switch.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Understanding the Differences Between Layer 2 and Layer 3 Switches<\/span><\/a><\/li>                <\/ul>\r\n                        <\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Active connectors are passive optical devices frequently used in conjunction with optical module interfaces. These connectors, which are attached to the optical side of a module, generally adhere to standardized processes to form universally accepted physical and performance interfaces, thereby enabling interoperability among various manufacturers. Standardization, as a process, involves achieving industry consensus. Over time, [&hellip;]<\/p>\n","protected":false},"author":227,"featured_media":16750,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":"","_wpscppro_dont_share_socialmedia":false,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"default","_instagram_share_type":"default","_medium_share_type":"","_threads_share_type":"","_google_business_share_type":"","_selected_social_profile":[{"id":"skM9ewvR8O","platform":"linkedin","platformKey":0,"name":"Jason Xue","type":"person","thumbnail_url":"https:\/\/media.licdn.com\/dms\/image\/C5603AQErPqKD0j6qBg\/profile-displayphoto-shrink_100_100\/0\/1599138392315?e=1723075200&v=beta&t=joEkh1OeKQ0F-QpAPv4xxQyBdGlHyccIQZauRSs6RvU","share_type":"default"}],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[2,28],"tags":[],"class_list":["post-16747","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-fiber-optic-cables"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v20.13 (Yoast SEO v25.8) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Active Connectors: LC, CS, SN, MPO, PC, APC - fibermall.com<\/title>\n<meta name=\"description\" content=\"Active connectors are passive optical devices frequently used in conjunction with optical module interfaces.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Active Connectors: LC, CS, SN, MPO, PC, APC\" \/>\n<meta property=\"og:description\" content=\"Active connectors are passive optical devices frequently used in conjunction with optical module interfaces. These connectors, which are attached to the\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm\" \/>\n<meta property=\"og:site_name\" content=\"fibermall.com\" \/>\n<meta property=\"article:published_time\" content=\"2025-04-01T06:37:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-01T06:37:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png\" \/>\n\t<meta property=\"og:image:width\" content=\"910\" \/>\n\t<meta property=\"og:image:height\" content=\"602\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Catherine\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Catherine\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm\"},\"author\":{\"name\":\"Catherine\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d\"},\"headline\":\"Active Connectors: LC, CS, SN, MPO, PC, APC\",\"datePublished\":\"2025-04-01T06:37:00+00:00\",\"dateModified\":\"2025-04-01T06:37:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm\"},\"wordCount\":571,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png\",\"articleSection\":[\"Blog\",\"Fiber Optic Cables\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm\",\"url\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm\",\"name\":\"Active Connectors: LC, CS, SN, MPO, PC, APC - fibermall.com\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png\",\"datePublished\":\"2025-04-01T06:37:00+00:00\",\"dateModified\":\"2025-04-01T06:37:51+00:00\",\"description\":\"Active connectors are passive optical devices frequently used in conjunction with optical module interfaces.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#primaryimage\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png\",\"width\":910,\"height\":602,\"caption\":\"Active-Connectors\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.fibermall.com\/blog.htm\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Active Connectors: LC, CS, SN, MPO, PC, APC\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"name\":\"fibermall.com\",\"description\":\"Optical Communication Expert\",\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\",\"name\":\"fibermall.com\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"width\":200,\"height\":67,\"caption\":\"fibermall.com\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d\",\"name\":\"Catherine\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g\",\"caption\":\"Catherine\"},\"description\":\"Optical Communications Engineer\",\"sameAs\":[\"https:\/\/www.fibermall.com\/\"],\"url\":\"https:\/\/www.fibermall.com\/blog.htm?author=227\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Active Connectors: LC, CS, SN, MPO, PC, APC - fibermall.com","description":"Active connectors are passive optical devices frequently used in conjunction with optical module interfaces.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm","og_locale":"en_US","og_type":"article","og_title":"Active Connectors: LC, CS, SN, MPO, PC, APC","og_description":"Active connectors are passive optical devices frequently used in conjunction with optical module interfaces. These connectors, which are attached to the","og_url":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm","og_site_name":"fibermall.com","article_published_time":"2025-04-01T06:37:00+00:00","article_modified_time":"2025-04-01T06:37:51+00:00","og_image":[{"width":910,"height":602,"url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png","type":"image\/png"}],"author":"Catherine","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Catherine","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#article","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm"},"author":{"name":"Catherine","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d"},"headline":"Active Connectors: LC, CS, SN, MPO, PC, APC","datePublished":"2025-04-01T06:37:00+00:00","dateModified":"2025-04-01T06:37:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm"},"wordCount":571,"commentCount":0,"publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png","articleSection":["Blog","Fiber Optic Cables"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm","url":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm","name":"Active Connectors: LC, CS, SN, MPO, PC, APC - fibermall.com","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#primaryimage"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png","datePublished":"2025-04-01T06:37:00+00:00","dateModified":"2025-04-01T06:37:51+00:00","description":"Active connectors are passive optical devices frequently used in conjunction with optical module interfaces.","breadcrumb":{"@id":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#primaryimage","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2025\/03\/Active-Connectors.png","width":910,"height":602,"caption":"Active-Connectors"},{"@type":"BreadcrumbList","@id":"https:\/\/www.fibermall.com\/blog\/active-connectors-lc-cs-sn-mpo-pc-apc.htm#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fibermall.com\/blog.htm"},{"@type":"ListItem","position":2,"name":"Active Connectors: LC, CS, SN, MPO, PC, APC"}]},{"@type":"WebSite","@id":"https:\/\/www.fibermall.com\/blog.htm\/#website","url":"https:\/\/www.fibermall.com\/blog.htm\/","name":"fibermall.com","description":"Optical Communication Expert","publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization","name":"fibermall.com","url":"https:\/\/www.fibermall.com\/blog.htm\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","width":200,"height":67,"caption":"fibermall.com"},"image":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d","name":"Catherine","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g","caption":"Catherine"},"description":"Optical Communications Engineer","sameAs":["https:\/\/www.fibermall.com\/"],"url":"https:\/\/www.fibermall.com\/blog.htm?author=227"}]}},"_links":{"self":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/16747","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/users\/227"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=16747"}],"version-history":[{"count":5,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/16747\/revisions"}],"predecessor-version":[{"id":16826,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/16747\/revisions\/16826"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/media\/16750"}],"wp:attachment":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=16747"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=16747"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=16747"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}