{"id":18504,"date":"2026-01-16T07:18:36","date_gmt":"2026-01-16T07:18:36","guid":{"rendered":"https:\/\/www.fibermall.com\/blog\/?p=18504"},"modified":"2026-01-16T08:17:13","modified_gmt":"2026-01-16T08:17:13","slug":"key-design-constraints-for-stack-osfp-optical-transceiver-cold-plate-liquid-cooling","status":"publish","type":"post","link":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm","title":{"rendered":"Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling"},"content":{"rendered":"\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\/#Foreword\" >Foreword&nbsp;<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\/#OSFP_Module_Body_Dimensions_Without_IHS\" >OSFP Module Body Dimensions (Without IHS)<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\/#Stack_Cage_for_Cold_Plate_Liquid_Cooling\" >Stack Cage for Cold Plate Liquid Cooling<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\/#Additional_OSFP_Module_Thermal_Mechanical_Requirements\" >Additional OSFP Module Thermal &amp; Mechanical Requirements<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\/#InsertionExtraction_Force\" >Insertion\/Extraction Force<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\/#Optical_Module_Flatness_Requirement\" >Optical Module Flatness Requirement\u00a0<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\/#Optical_Module_RHS_Downforce_Requirement\" >Optical Module RHS Downforce Requirement\u00a0<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\/#OSFP_Optical_Module_Cage_Cold_Plate_Physical_Samples\" >OSFP Optical Module Cage + Cold Plate Physical Samples<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\/#Summary\" >Summary<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Foreword\"><\/span><strong>Foreword<\/strong>&nbsp;<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The data center industry has already adopted 800G\/1.6T optical modules on a large scale, and the demand for cold plate liquid cooling of optical modules has increased significantly. To meet this industry demand, OSFP-MSA V5.22 version has added solutions applicable to cold plate liquid cooling. At present, there are already some solutions for single-layer optical modules in the industry, such as heat pipe + remote cold plate schemes, etc. However, for Stack cage optical modules with cold plate liquid cooling, no mature technical solution has been provided by the industry yet, and many suppliers are still prototyping and researching new technical solutions. This article summarizes and organizes the design constraints related to Stack-OSFP optical module cold plate liquid cooling as specified in the latest MSA protocol.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/HPE-Slingshot-400-Switch-at-SC24-1-800x600-1.jpg\" alt=\"HPE-Slingshot-400-Switch-at-SC24-1-800x600\" class=\"wp-image-18506\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/HPE-Slingshot-400-Switch-at-SC24-1-800x600-1.jpg 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/HPE-Slingshot-400-Switch-at-SC24-1-800x600-1-300x225.jpg 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/HPE-Slingshot-400-Switch-at-SC24-1-800x600-1-768x576.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"OSFP_Module_Body_Dimensions_Without_IHS\"><\/span><strong>OSFP Module Body Dimensions (Without IHS)<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>To accommodate cold plate liquid cooling for optical modules, the OSFP optical module needs to remove the IHS. At this time, the dimensions of the optical module body are as follows:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Module width 22.58 mm<\/li>\n\n\n\n<li>Module height 9.5 mm, with tolerance of -0.2 ~ 0.1 mm, i.e., the maximum dimensional deviation of the optical module body is 0.3 mm<\/li>\n\n\n\n<li>Allowed contact area with cold plate: 16.6 mm \u00d7 62.2 \u00b1 0.5 mm<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"606\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-size-1024x606.png\" alt=\"osfp size\" class=\"wp-image-18507\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-size-1024x606.png 1024w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-size-300x178.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-size-768x455.png 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-size.png 1071w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Stack_Cage_for_Cold_Plate_Liquid_Cooling\"><\/span><strong>Stack Cage for Cold Plate Liquid Cooling <\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>To meet the cold plate <a href=\"https:\/\/www.fibermall.com\/store-22018-800g-osfp-liquid-cooling.htm\" target=\"_blank\" rel=\"noreferrer noopener\">liquid cooling<\/a> requirement for dual-layer optical modules, the Stack cage dimensions have undergone significant changes. The cage is changed to a two-segment split type, which can support segmented installation:<\/p>\n\n\n\n<p>Height from the upper cover of the lower cage to the PCB board: 11.15 mm<\/p>\n\n\n\n<p>Dual-layer cage clearance height space: 9.5 mm, maximum depth 68 mm, can accommodate lower-layer optical module cold plate<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"428\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/port-height-of-osfp-rhs-1024x428.jpg\" alt=\"port height of osfp-rhs\" class=\"wp-image-18508\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/port-height-of-osfp-rhs-1024x428.jpg 1024w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/port-height-of-osfp-rhs-300x126.jpg 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/port-height-of-osfp-rhs-768x321.jpg 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/port-height-of-osfp-rhs-1536x643.jpg 1536w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/port-height-of-osfp-rhs.jpg 1568w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Total cage height: 31.05 mm Upper cage opening area: 61.6 \u00d7 18 mm, cold plate boss area must be smaller than this size to allow installation and fit the optical module.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"946\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/overview-of-osfp-rhs-1024x946.jpg\" alt=\"overview of osfp-rhs\" class=\"wp-image-18509\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/overview-of-osfp-rhs-1024x946.jpg 1024w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/overview-of-osfp-rhs-300x277.jpg 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/overview-of-osfp-rhs-768x710.jpg 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/overview-of-osfp-rhs.jpg 1056w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>To enhance cage strength, a certain width is reserved at the rear end, and the maximum opening size is adjusted to 58 \u00d7 18 mm.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"962\" height=\"1024\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/bottom-layer-962x1024.jpg\" alt=\"bottom layer\" class=\"wp-image-18510\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/bottom-layer-962x1024.jpg 962w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/bottom-layer-282x300.jpg 282w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/bottom-layer-768x818.jpg 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/bottom-layer.jpg 992w\" sizes=\"(max-width: 962px) 100vw, 962px\" \/><\/figure>\n\n\n\n<p>The length direction is reduced by 3.6 mm compared to the upper cage. If it is desired to keep the upper and lower layer optical module cold plate structures consistent, the design should follow the lower-layer opening dimensions at this time.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"260\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/EMI-finger-1024x260.jpg\" alt=\"EMI finger\" class=\"wp-image-18511\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/EMI-finger-1024x260.jpg 1024w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/EMI-finger-300x76.jpg 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/EMI-finger-768x195.jpg 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/EMI-finger-1536x390.jpg 1536w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/EMI-finger.jpg 2016w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>The net height dimension given for single-layer cage is 9.9 \u00b1 0.1 mm. It can be seen that the maximum possible gap range between the cage and the optical module is 0.2 ~ 0.7 mm.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Additional_OSFP_Module_Thermal_Mechanical_Requirements\"><\/span><strong>Additional OSFP Module Thermal &amp; Mechanical Requirements<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"InsertionExtraction_Force\"><\/span><strong>Insertion\/Extraction Force<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Maximum insertion force 40 N (with RHS maximum 55 N);<\/li>\n\n\n\n<li>Maximum extraction force 30 N (with RHS maximum 45 N). When the optical module adopts cold plate liquid cooling, it should be considered the same as the RHS scenario, so the maximum insertion force should be taken as 55 N.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"861\" height=\"387\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/insertion-extraction.png\" alt=\"insertion extraction\" class=\"wp-image-18521\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/insertion-extraction.png 861w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/insertion-extraction-300x135.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/insertion-extraction-768x345.png 768w\" sizes=\"(max-width: 861px) 100vw, 861px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Optical_Module_Flatness_Requirement\"><\/span><strong>Optical Module Flatness Requirement<\/strong>\u00a0<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>For scenarios above 14 W, corresponding to 800G and higher optical modules, the surface flatness of the optical module is required to be no higher than 0.05 mm, roughness Ra 0.8 \u03bcm. When designing the optical module cold plate, it should be designed according to this requirement.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"215\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/surface-flatness-1-1024x215.jpg\" alt=\"surface flatness\" class=\"wp-image-18522\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/surface-flatness-1-1024x215.jpg 1024w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/surface-flatness-1-300x63.jpg 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/surface-flatness-1-768x161.jpg 768w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/surface-flatness-1-1536x323.jpg 1536w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/surface-flatness-1-2048x430.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Optical_Module_RHS_Downforce_Requirement\"><\/span><strong>Optical Module RHS Downforce Requirement<\/strong>\u00a0<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The MSA protocol provides two clamping force requirements for <a href=\"https:\/\/www.fibermall.com\/store-21994-800g-ndr-infiniband.htm\" target=\"_blank\" rel=\"noreferrer noopener\">OSFP optical modules<\/a>, both for RHS: Section 5.5 requires not exceeding 36 N, Section 12.8 requires not exceeding 50 N. Since Chapter 12 of the MSA is a chapter specifically updated for OSFP optical modules after removing the IHS, and the cage structure in this chapter is designed with a clearance height of 9.5 mm, for Stack cages, it is recommended to design with a maximum downforce not exceeding 50 N when designing the optical module cold plate. Assuming the lower-layer cold plate contact area with the optical module is 16.6 \u00d7 50 mm, the surface pressure under 50 N downforce is approximately 8.3 psi. It can be seen that the contact pressure when the optical module contacts the cold plate is extremely low.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"OSFP_Optical_Module_Cage_Cold_Plate_Physical_Samples\"><\/span><strong>OSFP Optical Module Cage + Cold Plate Physical Samples <\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The cage structure prototyped according to this version of the MSA protocol is shown below. The lower-layer optical module cold plate needs to provide a highly reliable and relatively low-cost optical module cold plate liquid cooling solution within the dimensional constraints of height 9.5 mm and depth 68 mm.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"982\" height=\"566\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-cage.png\" alt=\"osfp cage\" class=\"wp-image-18514\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-cage.png 982w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-cage-300x173.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-cage-768x443.png 768w\" sizes=\"(max-width: 982px) 100vw, 982px\" \/><\/figure>\n\n\n\n<p>Currently, some connector manufacturers in the industry have already provided cold plate solutions for Stack cages. For example, the solution provided by Amphenol is an integrated cold plate that supports cold plate liquid cooling for 8 optical modules each on upper and lower layers simultaneously. According to official information, this cold plate has the following characteristics:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>One-piece cold plate shared by 8 optical modules each on upper and lower layers (total 16 ports);<\/li>\n\n\n\n<li>Maximum cooling capacity 40 W;<\/li>\n\n\n\n<li>Independent spring loading for each port to ensure contact;<\/li>\n\n\n\n<li>Only one inlet and one outlet for 16 optical modules, maximizing reliability and reducing leakage risk;<\/li>\n\n\n\n<li>Fluid water pressure does not affect insertion\/extraction force (indicating that the floating part does not contact the coolant, and there are no sliding seal or similar leakage scenarios).<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"734\" height=\"523\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-cage-2.png\" alt=\"osfp cage 2\" class=\"wp-image-18515\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-cage-2.png 734w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/osfp-cage-2-300x214.png 300w\" sizes=\"(max-width: 734px) 100vw, 734px\" \/><\/figure>\n\n\n\n<p>The actual heat dissipation performance of this solution after application still needs to be verified.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Summary\"><\/span><strong>Summary <\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>OSFP optical module is the mainstream form factor solution for 800G and 1.6T capacity. The heat dissipation performance and reliability of its cold plate liquid cooling solution are crucial to whether cold plate liquid cooling technology can be widely promoted and applied to optical module liquid cooling. The MSA has already provided the recommended structural design applicable to optical module cold plate liquid cooling. Subsequent cold plate solution designs should refer to the above key constraint information when designing OSFP optical module cold plates.<\/p>\n\n\n\n<p><\/p>\n<style>\r\n\r\n        .lwrp.link-whisper-related-posts{\r\n            \r\n            margin-top: 40px;\nmargin-bottom: 30px;\r\n        }\r\n        .lwrp .lwrp-title{\r\n            \r\n            \r\n        }\r\n        .lwrp .lwrp-description{\r\n            \r\n            \r\n\r\n        }\r\n        .lwrp .lwrp-list-container{\r\n        }\r\n        .lwrp .lwrp-list-multi-container{\r\n            display: flex;\r\n        }\r\n        .lwrp .lwrp-list-double{\r\n            width: 48%;\r\n        }\r\n        .lwrp .lwrp-list-triple{\r\n            width: 32%;\r\n        }\r\n        .lwrp .lwrp-list-row-container{\r\n            display: flex;\r\n            justify-content: space-between;\r\n        }\r\n        .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n            width: calc(100% - 20px);\r\n        }\r\n        .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n            \r\n            list-style: decimal;\r\n        }\r\n        .lwrp .lwrp-list-item img{\r\n            max-width: 100%;\r\n            height: auto;\r\n        }\r\n        .lwrp .lwrp-list-item.lwrp-empty-list-item{\r\n            background: initial !important;\r\n        }\r\n        .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n        .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n            \r\n                \r\n        }\r\n        @media screen and (max-width: 480px) {\r\n            .lwrp.link-whisper-related-posts{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-title{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-description{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-multi-container{\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-multi-container ul.lwrp-list{\r\n                margin-top: 0px;\r\n                margin-bottom: 0px;\r\n                padding-top: 0px;\r\n                padding-bottom: 0px;\r\n            }\r\n            .lwrp .lwrp-list-double,\r\n            .lwrp .lwrp-list-triple{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-row-container{\r\n                justify-content: initial;\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n            .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n                \r\n                    \r\n            }\r\n        }<\/style>\r\n<div id=\"link-whisper-related-posts-widget\" class=\"link-whisper-related-posts lwrp\">\r\n            <h3 class=\"lwrp-title\">Related Posts<\/h3>    \r\n        <div class=\"lwrp-list-container\">\r\n                                            <ul class=\"lwrp-list lwrp-list-single\">\r\n                    <li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/video\/100g-qsfp28-dac-vs-100g-qsfp28-transceiver.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">100G QSFP28 DAC VS 100G QSFP28 Transceiver<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/optical-transceiver-technology-trends-of-data-center-in-2022.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Optical Transceiver Technology Trends of Data Center in 2022<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/osfp-vs-qsfp-dd.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">OSFP vs QSFP-DD vs QSFP112: Which 400G\/800G Form Factor Should You Choose?<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/wdm-otn-transmission-technology.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">WDM\/OTN: Large-capacity transmission technology of network data<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/industrial-ethernet-switch.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">How to Select and Use Industrial Ethernet Switches<\/span><\/a><\/li>                <\/ul>\r\n                        <\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Foreword&nbsp; The data center industry has already adopted 800G\/1.6T optical modules on a large scale, and the demand for cold plate liquid cooling of optical modules has increased significantly. To meet this industry demand, OSFP-MSA V5.22 version has added solutions applicable to cold plate liquid cooling. At present, there are already some solutions for single-layer [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":18516,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":"","_wpscppro_dont_share_socialmedia":false,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"default","_instagram_share_type":"default","_medium_share_type":"default","_threads_share_type":"default","_google_business_share_type":"default","_selected_social_profile":[{"id":"skM9ewvR8O","platform":"linkedin","platformKey":0,"name":"Jason Xue","type":"person","thumbnail_url":"https:\/\/media.licdn.com\/dms\/image\/C5603AQErPqKD0j6qBg\/profile-displayphoto-shrink_100_100\/0\/1599138392315?e=1723075200&v=beta&t=joEkh1OeKQ0F-QpAPv4xxQyBdGlHyccIQZauRSs6RvU","share_type":"default"}],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[2,30],"tags":[],"class_list":["post-18504","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-fiber-optic-transceivers"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v20.13 (Yoast SEO v25.8) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling - fibermall.com<\/title>\n<meta name=\"description\" content=\"This article summarizes and organizes the design constraints related to Stack-OSFP optical module cold plate liquid cooling as specified in the latest MSA protocol.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling\" \/>\n<meta property=\"og:description\" content=\"Foreword&nbsp; The data center industry has already adopted 800G\/1.6T optical modules on a large scale, and the demand for cold plate liquid cooling of\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\" \/>\n<meta property=\"og:site_name\" content=\"fibermall.com\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-16T07:18:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-16T08:17:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/a8db1c053f36fb6eb5f3c40ad4b9192f_720.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Brian\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Brian\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\"},\"author\":{\"name\":\"Brian\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/9421292f8817d668e9e64f94dfe9b901\"},\"headline\":\"Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling\",\"datePublished\":\"2026-01-16T07:18:36+00:00\",\"dateModified\":\"2026-01-16T08:17:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\"},\"wordCount\":908,\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/a8db1c053f36fb6eb5f3c40ad4b9192f_720.jpg\",\"articleSection\":[\"Blog\",\"Fiber Optic Transceivers\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\",\"url\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\",\"name\":\"Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling - fibermall.com\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/a8db1c053f36fb6eb5f3c40ad4b9192f_720.jpg\",\"datePublished\":\"2026-01-16T07:18:36+00:00\",\"dateModified\":\"2026-01-16T08:17:13+00:00\",\"description\":\"This article summarizes and organizes the design constraints related to Stack-OSFP optical module cold plate liquid cooling as specified in the latest MSA protocol.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#primaryimage\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/a8db1c053f36fb6eb5f3c40ad4b9192f_720.jpg\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/a8db1c053f36fb6eb5f3c40ad4b9192f_720.jpg\",\"width\":900,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.fibermall.com\/blog.htm\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"name\":\"fibermall.com\",\"description\":\"Optical Communication Expert\",\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\",\"name\":\"fibermall.com\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"width\":200,\"height\":67,\"caption\":\"fibermall.com\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/9421292f8817d668e9e64f94dfe9b901\",\"name\":\"Brian\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/c196835c5ddcc99559fcfaa0046ffbd895891b78d40ab46bf34f7a5ecd73dfd9?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/c196835c5ddcc99559fcfaa0046ffbd895891b78d40ab46bf34f7a5ecd73dfd9?s=96&d=mm&r=g\",\"caption\":\"Brian\"},\"description\":\"Optical Network Engineer\",\"sameAs\":[\"https:\/\/www.fibermall.com\"],\"url\":\"https:\/\/www.fibermall.com\/blog.htm?author=5\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling - fibermall.com","description":"This article summarizes and organizes the design constraints related to Stack-OSFP optical module cold plate liquid cooling as specified in the latest MSA protocol.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm","og_locale":"en_US","og_type":"article","og_title":"Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling","og_description":"Foreword&nbsp; The data center industry has already adopted 800G\/1.6T optical modules on a large scale, and the demand for cold plate liquid cooling of","og_url":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm","og_site_name":"fibermall.com","article_published_time":"2026-01-16T07:18:36+00:00","article_modified_time":"2026-01-16T08:17:13+00:00","og_image":[{"width":900,"height":600,"url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/a8db1c053f36fb6eb5f3c40ad4b9192f_720.jpg","type":"image\/jpeg"}],"author":"Brian","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Brian","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#article","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm"},"author":{"name":"Brian","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/9421292f8817d668e9e64f94dfe9b901"},"headline":"Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling","datePublished":"2026-01-16T07:18:36+00:00","dateModified":"2026-01-16T08:17:13+00:00","mainEntityOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm"},"wordCount":908,"publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/a8db1c053f36fb6eb5f3c40ad4b9192f_720.jpg","articleSection":["Blog","Fiber Optic Transceivers"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm","url":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm","name":"Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling - fibermall.com","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#primaryimage"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/a8db1c053f36fb6eb5f3c40ad4b9192f_720.jpg","datePublished":"2026-01-16T07:18:36+00:00","dateModified":"2026-01-16T08:17:13+00:00","description":"This article summarizes and organizes the design constraints related to Stack-OSFP optical module cold plate liquid cooling as specified in the latest MSA protocol.","breadcrumb":{"@id":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#primaryimage","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/a8db1c053f36fb6eb5f3c40ad4b9192f_720.jpg","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/01\/a8db1c053f36fb6eb5f3c40ad4b9192f_720.jpg","width":900,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/www.fibermall.com\/blog\/key-design-for-stack-osfp-transceiver.htm#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fibermall.com\/blog.htm"},{"@type":"ListItem","position":2,"name":"Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling"}]},{"@type":"WebSite","@id":"https:\/\/www.fibermall.com\/blog.htm\/#website","url":"https:\/\/www.fibermall.com\/blog.htm\/","name":"fibermall.com","description":"Optical Communication Expert","publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization","name":"fibermall.com","url":"https:\/\/www.fibermall.com\/blog.htm\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","width":200,"height":67,"caption":"fibermall.com"},"image":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/9421292f8817d668e9e64f94dfe9b901","name":"Brian","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/c196835c5ddcc99559fcfaa0046ffbd895891b78d40ab46bf34f7a5ecd73dfd9?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c196835c5ddcc99559fcfaa0046ffbd895891b78d40ab46bf34f7a5ecd73dfd9?s=96&d=mm&r=g","caption":"Brian"},"description":"Optical Network Engineer","sameAs":["https:\/\/www.fibermall.com"],"url":"https:\/\/www.fibermall.com\/blog.htm?author=5"}]}},"_links":{"self":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/18504","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=18504"}],"version-history":[{"count":4,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/18504\/revisions"}],"predecessor-version":[{"id":18524,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/18504\/revisions\/18524"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/media\/18516"}],"wp:attachment":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=18504"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=18504"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=18504"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}