{"id":19907,"date":"2026-07-27T06:57:00","date_gmt":"2026-07-27T06:57:00","guid":{"rendered":"https:\/\/www.fibermall.com\/blog\/?p=19907"},"modified":"2026-07-29T02:07:20","modified_gmt":"2026-07-29T02:07:20","slug":"qsfp-cmis-ddm-eeprom-a-practical-engineers-guide","status":"publish","type":"post","link":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm","title":{"rendered":"QSFP CMIS DDM EEPROM: A Practical Engineer&#8217;s Guide"},"content":{"rendered":"\n<p>At 2:17 a.m., Priya&#8217;s phone buzzed. A 400G spine link in her Singapore data center had flapped. She logged into the switch and ran ethtool -m eth0\/1. The output was there: a QSFP-DD module, vendor name, serial number, and a line that read Module State: 0x02 (ModuleLowPwr). The link wasn&#8217;t down because of a bad fiber. It was down because the module hadn&#8217;t made it past its own power-up handshake. That&#8217;s the moment she needed the full <strong>qsfp cmis ddm eeprom<\/strong>&nbsp;picture, not just a cable tester.<\/p>\n\n\n\n<p>If you&#8217;ve ever stared at transceiver diagnostics and wondered what the numbers actually mean, you&#8217;re not alone. Every modern QSFP, QSFP28, and QSFP-DD module carries a small EEPROM that holds its identity, its capabilities, and a stream of real-time health data called DDM. The way you read that EEPROM depends on whether the module speaks the older SFF-8636 protocol or the newer CMIS protocol. This guide breaks down both so you can read, interpret, and act on module diagnostics with confidence.<\/p>\n\n\n\n<p><strong>Need QSFP modules with reliable DDM support?<\/strong>&nbsp;Explore FiberMall&#8217;s optical transceiver solutions&nbsp;or contact our networking experts&nbsp;for a compatibility review.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Quick_Verdict\" >Quick Verdict<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#What_CMIS_DDM_and_EEPROM_Actually_Do\" >What CMIS, DDM, and EEPROM Actually Do<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#CMIS_Common_Management_Interface_Specification\" >CMIS (Common Management Interface Specification)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#DDM_DOM_Digital_Diagnostic_Monitoring\" >DDM \/ DOM (Digital Diagnostic Monitoring)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#EEPROM\" >EEPROM<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Standards_Map_SFF-8472_SFF-8636_and_CMIS\" >Standards Map: SFF-8472, SFF-8636, and CMIS<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#QSFP28_and_the_SFF-8636_EEPROM_Layout\" >QSFP28 and the SFF-8636 EEPROM Layout<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Lower_Page_0x00%E2%80%930x7F\" >Lower Page (0x00\u20130x7F)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Upper_Pages\" >Upper Pages<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#QSFP-DD_and_the_CMIS_EEPROM_Layout\" >QSFP-DD and the CMIS EEPROM Layout<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Lower_Page_0x00%E2%80%930x7F-2\" >Lower Page (0x00\u20130x7F)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Upper_Pages-2\" >Upper Pages<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Reading_QSFP_EEPROM_A_CLI_Cheat_Sheet\" >Reading QSFP EEPROM: A CLI Cheat Sheet<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Linux_ethtool_-m\" >Linux: ethtool -m<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#SONiC_Broadcom_sfputil\" >SONiC \/ Broadcom: sfputil<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Cisco_IOS-XR_NX-OS\" >Cisco IOS-XR \/ NX-OS<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Mellanox_NVIDIA_mlxlink\" >Mellanox \/ NVIDIA: mlxlink<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Arista_EOS\" >Arista EOS<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Understanding_DDM_Thresholds_and_Alarms\" >Understanding DDM Thresholds and Alarms<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#How_Alarms_Reach_the_Host\" >How Alarms Reach the Host<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#CMIS_State_Machine_and_Common_Failures\" >CMIS State Machine and Common Failures<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Advanced_Diagnostics_VDM_and_FEC\" >Advanced Diagnostics: VDM and FEC<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#2026_Outlook_CMIS_54_800G_and_16T\" >2026 Outlook: CMIS 5.4, 800G, and 1.6T<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Quick_Verdict\"><\/span><strong>Quick Verdict<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>If you just need the bottom line, here&#8217;s what matters:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>QSFP+\/QSFP28 modules<\/strong>\u00a0use the <strong>SFF-8636<\/strong>\u00a0management interface. EEPROM is paged at I\u00b2C address 0xA0.<\/li>\n\n\n\n<li><strong>QSFP-DD, OSFP, and 800G modules<\/strong>\u00a0use <strong>CMIS<\/strong>. EEPROM uses a lower page plus banked upper pages at the same I\u00b2C address.<\/li>\n\n\n\n<li><strong>DDM<\/strong>\u00a0reports temperature, voltage, TX\/RX power, and bias current in real time.<\/li>\n\n\n\n<li><strong>EEPROM decode errors<\/strong>\u00a0usually mean a firmware or CMIS-version mismatch, not a dead module.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/What-CMIS-DDM-and-EEPROM-Actually-Do.png\" alt=\"What CMIS, DDM, and EEPROM Actually Do\" class=\"wp-image-19908\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/What-CMIS-DDM-and-EEPROM-Actually-Do.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/What-CMIS-DDM-and-EEPROM-Actually-Do-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/What-CMIS-DDM-and-EEPROM-Actually-Do-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_CMIS_DDM_and_EEPROM_Actually_Do\"><\/span><strong>What CMIS, DDM, and EEPROM Actually Do<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"CMIS_Common_Management_Interface_Specification\"><\/span><strong>CMIS (Common Management Interface Specification)<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>CMIS is the standardized protocol a host switch uses to talk to a modern pluggable module.<\/p>\n\n\n\n<p>It was developed by the QSFP-DD MSA and is now maintained by the Optical Internetworking Forum (OIF). CMIS handles identification, power negotiation, application selection, alarms, and firmware updates. Without it, a switch wouldn&#8217;t know whether a <a href=\"https:\/\/www.fibermall.com\/sale-452811-qsfp-dd-400g-sr8-850nm-100m.htm\" target=\"_blank\" rel=\"noreferrer noopener\">QSFP-DD module is a 400G SR8<\/a>, a 2\u00d7200G breakout, or an 800G FR4.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"DDM_DOM_Digital_Diagnostic_Monitoring\"><\/span><strong>DDM \/ DOM (Digital Diagnostic Monitoring)<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>DDM is the live telemetry stream. It tells you the module&#8217;s temperature, supply voltage, laser bias current, transmitted optical power, and received optical power, usually per lane. Some vendors call it DOM; it&#8217;s the same idea. DDM is what turns a dumb optic into a sensor you can monitor.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"EEPROM\"><\/span><strong>EEPROM<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>EEPROM is the module&#8217;s non-volatile storage. It holds the serial ID, vendor name, part number, date code, capability bits, alarm thresholds, and sometimes user-writable fields. When you run ethtool -m, you&#8217;re reading bytes out of this EEPROM.<\/p>\n\n\n\n<p>For a broader look at the QSFP family, see FiberMall&#8217;s <a href=\"https:\/\/www.fibermall.com\/blog\/qsfp-transceiver-guide.htm\" target=\"_blank\"><u>QSFP transceiver guide.<\/u><\/a><\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container \" style=\"height: 100%;\"><iframe title=\"400G QSFP-DD DR4 Transceiver: High-Density Connectivity | FiberMall\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/nsdnojBDGrw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Standards_Map_SFF-8472_SFF-8636_and_CMIS\"><\/span><strong>Standards Map: SFF-8472, SFF-8636, and CMIS<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Not every form factor uses the same management spec. The table below maps the common standards to the modules you&#8217;re likely to see in 2026.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Form Factors<\/strong><\/td><td><strong>Management Spec<\/strong><\/td><td><strong>Typical Speeds<\/strong><\/td><td><strong>EEPROM Model<\/strong><\/td><\/tr><tr><td>SFP, SFP+, SFP28<\/td><td>SFF-8472<\/td><td>1G\u201325G<\/td><td>Two 256-byte blocks at 0xA0&nbsp;and 0xA2<\/td><\/tr><tr><td>QSFP+, QSFP28, QSFP56<\/td><td>SFF-8636<\/td><td>40G\u2013200G<\/td><td>256-byte window with paged upper 128 bytes<\/td><\/tr><tr><td>QSFP-DD, OSFP, QSFP112<\/td><td>CMIS<\/td><td>200G\u2013800G+<\/td><td>Lower 128 bytes + banked upper pages<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>The jump from SFF-8636 to CMIS wasn&#8217;t just a bigger address space. CMIS added dynamic application advertisement, power-mode control, and a state machine the host must follow before traffic can flow. LINK-PP has a useful SFF-8636 vs CMIS comparison&nbsp;if you want the full evolution story.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"QSFP28_and_the_SFF-8636_EEPROM_Layout\"><\/span><strong>QSFP28 and the SFF-8636 EEPROM Layout<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>A QSFP28 module exposes a single I\u00b2C address: 0xA0&nbsp;for reads. The memory is organized as a 256-byte window with a fixed lower half and a selected upper half.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Lower_Page_0x00%E2%80%930x7F\"><\/span><strong>Lower Page (0x00\u20130x7F)<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The lower page holds time-critical data:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Bytes 0\u20132:<\/strong>\u00a0Identifier and status bytes.<\/li>\n\n\n\n<li><strong>Bytes 3\u201321:<\/strong>\u00a0Interrupt flags.<\/li>\n\n\n\n<li><strong>Bytes 22\u201333:<\/strong>\u00a0Module-wide monitors (temperature, Vcc).<\/li>\n\n\n\n<li><strong>Bytes 34\u201381:<\/strong>\u00a0Channel monitors (per-lane TX\/RX power, TX bias).<\/li>\n\n\n\n<li><strong>Bytes 86\u201399:<\/strong>\u00a0Control bytes.<\/li>\n\n\n\n<li><strong>Bytes 100\u2013106:<\/strong>\u00a0Interrupt masks.<\/li>\n\n\n\n<li><strong>Byte 127:<\/strong>\u00a0Page-select byte.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Upper_Pages\"><\/span><strong>Upper Pages<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>To read the upper pages, you write a page number to byte 127 and then read addresses 0x80\u20130xFF:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Page 00h:<\/strong>\u00a0Serial ID fields (vendor name, OUI, part number, serial number, date code, power class).<\/li>\n\n\n\n<li><strong>Page 01h:<\/strong>\u00a0Application \/ option table.<\/li>\n\n\n\n<li><strong>Page 02h:<\/strong>\u00a0User-writable EEPROM.<\/li>\n\n\n\n<li><strong>Page 03h:<\/strong>\u00a0Alarm and warning thresholds.<\/li>\n<\/ul>\n\n\n\n<p>Real-time diagnostics live in the lower page, so a switch can poll temperature and optical power without constantly changing pages.<\/p>\n\n\n\n<p>For the exact electrical pinout behind that I\u00b2C bus, see FiberMall&#8217;s <a href=\"https:\/\/www.fibermall.com\/blog\/qsfp-pinout-msa-sff-8436-38-pin-guide.htm\" target=\"_blank\"><u>QSFP pinout and MSA guide.<\/u><\/a><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/QSFP28-and-the-SFF-8636-EEPROM-Layout.png\" alt=\"QSFP28 and the SFF-8636 EEPROM Layout\" class=\"wp-image-19909\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/QSFP28-and-the-SFF-8636-EEPROM-Layout.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/QSFP28-and-the-SFF-8636-EEPROM-Layout-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/QSFP28-and-the-SFF-8636-EEPROM-Layout-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"QSFP-DD_and_the_CMIS_EEPROM_Layout\"><\/span><strong>QSFP-DD and the CMIS EEPROM Layout<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>CMIS keeps the same 0xA0&nbsp;I\u00b2C address but reorganizes the memory into a lower page that is always visible and upper pages that are banked.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Lower_Page_0x00%E2%80%930x7F-2\"><\/span><strong>Lower Page (0x00\u20130x7F)<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The lower page contains the data a host needs most often:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Byte 0:<\/strong>\u00a0Identifier.<\/li>\n\n\n\n<li><strong>Byte 3:<\/strong>\u00a0Module state (the bits Priya was staring at).<\/li>\n\n\n\n<li><strong>Bytes 14\u201325:<\/strong>\u00a0Module-level monitors (temperature, Vcc, auxiliary monitors).<\/li>\n\n\n\n<li><strong>Bytes 26\u201381:<\/strong>\u00a0Lane-specific monitors (TX\/RX power, TX bias, per-lane flags).<\/li>\n\n\n\n<li><strong>Bytes 86\u201399:<\/strong>\u00a0Control fields.<\/li>\n\n\n\n<li><strong>Byte 127:<\/strong>\u00a0Page-select byte.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Upper_Pages-2\"><\/span><strong>Upper Pages<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Page 00h:<\/strong>\u00a0Administrative information (vendor name, OUI, part number, serial number, date code, power characteristics, connector type).<\/li>\n\n\n\n<li><strong>Page 01h:<\/strong>\u00a0Application advertising table.<\/li>\n\n\n\n<li><strong>Page 02h:<\/strong>\u00a0Thresholds.<\/li>\n\n\n\n<li><strong>Pages 10h\u201311h:<\/strong>\u00a0Data-path control and status.<\/li>\n\n\n\n<li><strong>Banked pages:<\/strong>\u00a0Additional lanes and advanced diagnostics for 800G\/1.6T modules.<\/li>\n<\/ul>\n\n\n\n<p>CMIS also introduces an explicit state machine. The module won&#8217;t move data until the host walks it from ModuleLowPwr&nbsp;through ModuleReady&nbsp;and into DataPathActivated. Skipping that handshake is a common reason a module is detected but the link stays dark.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/QSFP-DD-and-the-CMIS-EEPROM-Layout.png\" alt=\"QSFP-DD and the CMIS EEPROM Layout\" class=\"wp-image-19910\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/QSFP-DD-and-the-CMIS-EEPROM-Layout.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/QSFP-DD-and-the-CMIS-EEPROM-Layout-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/QSFP-DD-and-the-CMIS-EEPROM-Layout-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Reading_QSFP_EEPROM_A_CLI_Cheat_Sheet\"><\/span><strong>Reading QSFP EEPROM: A CLI Cheat Sheet<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Linux_ethtool_-m\"><\/span><strong>Linux: ethtool -m<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>On most Linux switches and servers, this is the fastest check:<\/p>\n\n\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;ethtool -m eth1 &nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<p>Add &#8211;verbose&nbsp;or use ethtool &#8211;show-module eth1&nbsp;on newer kernels to see power-mode policy and CMIS state. Wolontek&#8217;s practical EEPROM guide&nbsp;notes that a &#8220;Connection timed out&#8221; error usually means an I\u00b2C bus hang; re-seat the module first.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"SONiC_Broadcom_sfputil\"><\/span><strong>SONiC \/ Broadcom: sfputil<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;sfputil show eeprom -p Ethernet0 &#8211;dom &nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<p>The &#8211;dom&nbsp;flag includes DDM values. Omit it for a clean serial-ID dump.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Cisco_IOS-XR_NX-OS\"><\/span><strong>Cisco IOS-XR \/ NX-OS<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;show interface transceiver detail &nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;show controllers optics R0\/RP0\/CPU0 &nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Mellanox_NVIDIA_mlxlink\"><\/span><strong>Mellanox \/ NVIDIA: mlxlink<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;mlxlink -d \/dev\/mst\/mt52100_pciconf0 -c &#8211;show_module &#8211;cable &#8211;dump &nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<p>mlxlink&nbsp;gives raw page dumps and state-machine status, which is invaluable when a module is stuck.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Arista_EOS\"><\/span><strong>Arista EOS<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;show interfaces transceiver eeprom &nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;show interfaces transceiver dom &nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<p>Keep this cheat sheet handy. When a link fails at 2 a.m., the right command saves a lot of guesswork.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/Reading-QSFP-EEPROM-A-CLI-Cheat-Sheet.png\" alt=\"Reading QSFP EEPROM A CLI Cheat Sheet\" class=\"wp-image-19911\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/Reading-QSFP-EEPROM-A-CLI-Cheat-Sheet.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/Reading-QSFP-EEPROM-A-CLI-Cheat-Sheet-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/Reading-QSFP-EEPROM-A-CLI-Cheat-Sheet-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Understanding_DDM_Thresholds_and_Alarms\"><\/span><strong>Understanding DDM Thresholds and Alarms<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>DDM isn&#8217;t just numbers. Every monitored parameter has four thresholds: high alarm, high warning, low warning, and low alarm. The exact values are vendor- and module-specific, stored in the EEPROM.<\/p>\n\n\n\n<p>A typical QSFP+ threshold set from NVIDIA&#8217;s MFT documentation looks like this:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Parameter<\/strong><\/td><td><strong>High Alarm<\/strong><\/td><td><strong>High Warning<\/strong><\/td><td><strong>Low Warning<\/strong><\/td><td><strong>Low Alarm<\/strong><\/td><\/tr><tr><td>Temperature<\/td><td>80\u00b0C<\/td><td>70\u00b0C<\/td><td>0\u00b0C<\/td><td>\u201310\u00b0C<\/td><\/tr><tr><td>Voltage<\/td><td>3.500 V<\/td><td>3.465 V<\/td><td>3.135 V<\/td><td>3.100 V<\/td><\/tr><tr><td>RX Power<\/td><td>+5.4 dBm<\/td><td>+2.4 dBm<\/td><td>\u201310.3 dBm<\/td><td>\u201313.3 dBm<\/td><\/tr><tr><td>TX Power<\/td><td>+5.4 dBm<\/td><td>+2.4 dBm<\/td><td>\u20138.4 dBm<\/td><td>\u201311.4 dBm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Marcus, a network engineer in Frankfurt, once chased a &#8220;flapping&#8221; 100G link for an hour. The RX power looked fine at \u20136 dBm. Then he noticed the low-warning threshold was \u201310.3 dBm and the value was bouncing between \u201310.2 and \u201310.5 dBm. A dirty MPO connector was the culprit. A cleaning pen fixed it in 30 seconds. DDM didn&#8217;t just show a problem; it showed <em>which<\/em>&nbsp;problem.<\/p>\n\n\n\n<p>For modules running hotter than expected, FiberMall&#8217;s <a href=\"https:\/\/www.fibermall.com\/blog\/qsfp-power-consumption-per-gigabit-40g-800g-guide.htm\" target=\"_blank\"><u>QSFP power consumption guide <\/u><\/a>explains how thermal budget affects reliability.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/Understanding-DDM-Thresholds-and-Alarms.png\" alt=\"Understanding DDM Thresholds and Alarms\" class=\"wp-image-19912\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/Understanding-DDM-Thresholds-and-Alarms.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/Understanding-DDM-Thresholds-and-Alarms-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/Understanding-DDM-Thresholds-and-Alarms-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Alarms_Reach_the_Host\"><\/span><strong>How Alarms Reach the Host<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Most switches don&#8217;t sit and poll every byte of the EEPROM continuously. Instead, they rely on interrupt flags and masks. In SFF-8636, the lower page contains flag bytes that flip when a monitored value crosses a threshold. The host can mask individual flags so it only gets alerted for the conditions it cares about.<\/p>\n\n\n\n<p>CMIS uses a similar model. The lower page carries summary flags, and the upper banked pages expose lane-specific alarm bits. When a flag asserts, the host reads the relevant monitor bytes to find the offending lane or parameter. That&#8217;s why a good NMS integration maps DDM thresholds to actionable tickets rather than just logging raw numbers.<\/p>\n\n\n\n<p>If you&#8217;re writing automation, expose the alarm bits first and the raw telemetry second. An alarm bit tells you <em>that<\/em>&nbsp;something needs attention; the raw value tells you <em>how much<\/em>&nbsp;attention it needs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"CMIS_State_Machine_and_Common_Failures\"><\/span><strong>CMIS State Machine and Common Failures<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>CMIS modules don&#8217;t simply power on and pass traffic. They run a handshake:<\/p>\n\n\n\n<p>1. <strong>Reset<\/strong>&nbsp;\u2192 module boots.<\/p>\n\n\n\n<p>2. <strong>MgmtInit<\/strong>&nbsp;\u2192 module prepares the management interface.<\/p>\n\n\n\n<p>3. <strong>ModuleLowPwr<\/strong>&nbsp;\u2192 low-power mode, safe to insert.<\/p>\n\n\n\n<p>4. <strong>ModuleReady<\/strong>&nbsp;\u2192 high-power mode available.<\/p>\n\n\n\n<p>5. <strong>DataPathActivated<\/strong>&nbsp;\u2192 the selected application is running.<\/p>\n\n\n\n<p>A module can get stuck at any step. Common causes include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Power-class mismatch:<\/strong>\u00a0The switch doesn&#8217;t supply enough current for a Class 8 QSFP-DD module.<\/li>\n\n\n\n<li><strong>CMIS version mismatch:<\/strong>\u00a0A CMIS 5.0 module behind a CMIS 4.0-aware host may expose registers the host doesn&#8217;t parse correctly.<\/li>\n\n\n\n<li><strong>Application not selected:<\/strong>\u00a0The host never sent the correct Application Code, so the module never enters DataPathActivated.<\/li>\n\n\n\n<li><strong>Vendor lock-in:<\/strong>\u00a0Some switches reject third-party optics by checking vendor OUI fields in Page 00h.<\/li>\n<\/ul>\n\n\n\n<p>Priya&#8217;s ModuleLowPwr&nbsp;state turned out to be a firmware bug. The switch&#8217;s power-mode policy defaulted to low power for new third-party modules. A single ethtool &#8211;set-module eth0\/1 power-mode-policy high&nbsp;command nudged the module into ModuleReady, and the spine link came up. The EEPROM data was correct the whole time; the host just hadn&#8217;t finished the handshake.<\/p>\n\n\n\n<p>Ascent Optics covers more CMIS troubleshooting patterns in its QSFP-DD problem-resolution guide.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/CMIS-State-Machine-and-Common-Failures.png\" alt=\"CMIS State Machine and Common Failures\" class=\"wp-image-19913\" style=\"width:800px\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/CMIS-State-Machine-and-Common-Failures.png 800w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/CMIS-State-Machine-and-Common-Failures-300x169.png 300w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/CMIS-State-Machine-and-Common-Failures-768x432.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Advanced_Diagnostics_VDM_and_FEC\"><\/span><strong>Advanced Diagnostics: VDM and FEC<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>CMIS 5.0 and later add VDM, or Versatile Diagnostic Monitoring. VDM exposes richer per-lane data than traditional DDM:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pre-FEC bit error ratio<\/li>\n\n\n\n<li>Post-FEC frame error count<\/li>\n\n\n\n<li>Electrical SNR<\/li>\n\n\n\n<li>PAM level transition parameter (LTP)<\/li>\n\n\n\n<li>Equalizer settings<\/li>\n<\/ul>\n\n\n\n<p>These values matter most in AI training clusters and hyperscale fabrics, where a link can look healthy by optical power but still produce silent packet errors. FEC monitoring lets you catch degradation before it becomes packet loss.<\/p>\n\n\n\n<p>For 400G\/800G modules, VDM is becoming as important as temperature and RX power. If you&#8217;re building AI infrastructure, you need optics that expose these registers cleanly.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2026_Outlook_CMIS_54_800G_and_16T\"><\/span><strong>2026 Outlook: CMIS 5.4, 800G, and 1.6T<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>CMIS 5.3 is the current revision, released by the OIF in September 2024, with Errata 1.0 following in February 2025. CMIS 5.4 is expected in 2026. Each revision adds support for higher speeds, more lanes, and richer diagnostics.<\/p>\n\n\n\n<p>In 2026, <a href=\"https:\/\/www.fibermall.com\/store-21972-800g-qsfp-dd-osfp.htm\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>QSFP-DD800<\/strong>\u00a0modules<\/a> are mainstream, and <strong>1.6T OSFP-XD<\/strong>\u00a0modules are entering early deployment. Both rely on CMIS 5.x. The days of treating transceivers as simple plug-and-play parts are ending; they&#8217;re now managed peripherals with firmware, state machines, and telemetry.<\/p>\n\n\n\n<p>Vitex Tech&#8217;s EEPROM guide for AI data centers&nbsp;makes the same point: understanding EEPROM and CMIS is no longer optional for engineers building high-speed networks.<\/p>\n\n\n\n<p>If you&#8217;re evaluating 400G or 800G modules, FiberMall&#8217;s QSFP-DD vs QSFP28 vs OSFP comparison&nbsp;walks through the form-factor trade-offs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span><strong>Conclusion<\/strong><strong><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The <strong>qsfp cmis ddm eeprom<\/strong>&nbsp;stack is simpler than it looks once you separate the pieces. CMIS is the conversation between host and module. DDM is the live health data. EEPROM is the module&#8217;s identity and configuration store. SFF-8636 handles 40G\u2013200G QSFP modules; CMIS handles 200G\u20131.6T QSFP-DD and OSFP modules.<\/p>\n\n\n\n<p>When a link misbehaves, start with ethtool -m&nbsp;or your platform&#8217;s equivalent. Check the module state. Compare live DDM values against thresholds. If the module is detected but the link won&#8217;t come up, suspect the CMIS handshake before you suspect the fiber.<\/p>\n\n\n\n<p>If you need QSFP28, QSFP-DD, or OSFP modules with full DDM and CMIS compliance, explore FiberMall&#8217;s optical transceiver solutions&nbsp;or contact our networking experts&nbsp;for a deployment review.<\/p>\n<style>\r\n\r\n        .lwrp.link-whisper-related-posts{\r\n            \r\n            margin-top: 40px;\nmargin-bottom: 30px;\r\n        }\r\n        .lwrp .lwrp-title{\r\n            \r\n            \r\n        }\r\n        .lwrp .lwrp-description{\r\n            \r\n            \r\n\r\n        }\r\n        .lwrp .lwrp-list-container{\r\n        }\r\n        .lwrp .lwrp-list-multi-container{\r\n            display: flex;\r\n        }\r\n        .lwrp .lwrp-list-double{\r\n            width: 48%;\r\n        }\r\n        .lwrp .lwrp-list-triple{\r\n            width: 32%;\r\n        }\r\n        .lwrp .lwrp-list-row-container{\r\n            display: flex;\r\n            justify-content: space-between;\r\n        }\r\n        .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n            width: calc(100% - 20px);\r\n        }\r\n        .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n            \r\n            list-style: decimal;\r\n        }\r\n        .lwrp .lwrp-list-item img{\r\n            max-width: 100%;\r\n            height: auto;\r\n        }\r\n        .lwrp .lwrp-list-item.lwrp-empty-list-item{\r\n            background: initial !important;\r\n        }\r\n        .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n        .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n            \r\n                \r\n        }\r\n        @media screen and (max-width: 480px) {\r\n            .lwrp.link-whisper-related-posts{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-title{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-description{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-multi-container{\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-multi-container ul.lwrp-list{\r\n                margin-top: 0px;\r\n                margin-bottom: 0px;\r\n                padding-top: 0px;\r\n                padding-bottom: 0px;\r\n            }\r\n            .lwrp .lwrp-list-double,\r\n            .lwrp .lwrp-list-triple{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-row-container{\r\n                justify-content: initial;\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n            .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n                \r\n                    \r\n            }\r\n        }<\/style>\r\n<div id=\"link-whisper-related-posts-widget\" class=\"link-whisper-related-posts lwrp\">\r\n            <h3 class=\"lwrp-title\">Related Posts<\/h3>    \r\n        <div class=\"lwrp-list-container\">\r\n                                            <ul class=\"lwrp-list lwrp-list-single\">\r\n                    <li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/qsfp-transceiver-guide.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">What Is a QSFP Transceiver? The Complete QSFP Family Guide (40G\u2013800G)<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/qsfp-connector-cage-port-400g-800g-guide.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">QSFP Connector Cage Port: A Design Engineer&#8217;s 400G\/800G Selection Guide<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/qsfp-vs-qsfp28-vs-qsfp56.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">QSFP+ vs QSFP28 vs QSFP56: What&#8217;s the Difference? (2026)<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cables.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">The Ultimate Guide to QSFP+ Cables: Everything You Need to Know About 40G Connectivity<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/types-of-25g-sfp28-transceivers-vs-qsfp28-vs-qsfp.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Types of 25G SFP28 transceivers and differences vs QSFP28 vs QSFP+<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/video\/40gbase-er4-qsfp-transceiver-module.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">40GBase-ER4 QSFP+ Transceiver Module: How Much Do You Know?<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/video\/40gbase-sr4-qsfp-optical-transceiver.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">2 Minutes to Understand What&#8217;s 40GBASE SR4 QSFP+ Optical Transceiver<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/video\/40gbase-ir4-qsfp-optical-module.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">What is 40GBASE-IR4 QSFP+ optical module and how does it work?<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/video\/40g-qsfp-dac-cable.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">40G QSFP+ DAC cable: how much do you know?<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/what-type-of-40g-qsfp-optical-module-dac-aoc.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">What are the Types\u00a0of 40G QSFP+ Optical Modules, DAC, AOC\u00a0<\/span><\/a><\/li>                <\/ul>\r\n                        <\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"<p>At 2:17 a.m., Priya&#8217;s phone buzzed. A 400G spine link in her Singapore data center had flapped. She logged into the switch and ran ethtool -m eth0\/1. The output was there: a QSFP-DD module, vendor name, serial number, and a line that read Module State: 0x02 (ModuleLowPwr). The link wasn&#8217;t down because of a bad [&hellip;]<\/p>\n","protected":false},"author":227,"featured_media":19914,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":"","_wpscppro_dont_share_socialmedia":false,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"default","_instagram_share_type":"default","_medium_share_type":"default","_threads_share_type":"default","_google_business_share_type":"default","_selected_social_profile":[{"id":"skM9ewvR8O","platform":"linkedin","platformKey":0,"name":"Jason Xue","type":"person","thumbnail_url":"https:\/\/media.licdn.com\/dms\/image\/C5603AQErPqKD0j6qBg\/profile-displayphoto-shrink_100_100\/0\/1599138392315?e=1723075200&v=beta&t=joEkh1OeKQ0F-QpAPv4xxQyBdGlHyccIQZauRSs6RvU","share_type":"default"}],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[2,29],"tags":[],"class_list":["post-19907","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-networking"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v20.13 (Yoast SEO v25.8) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>QSFP CMIS DDM EEPROM: A Practical Engineer&#039;s Guide<\/title>\n<meta name=\"description\" content=\"Learn how QSFP CMIS, DDM, and EEPROM work together. Compare SFF-8636 and CMIS memory maps, read EEPROM with CLI tools, and interpret alarms.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"QSFP CMIS DDM EEPROM: A Practical Engineer&#039;s Guide\" \/>\n<meta property=\"og:description\" content=\"At 2:17 a.m., Priya&#039;s phone buzzed. A 400G spine link in her Singapore data center had flapped. She logged into the switch and ran ethtool -m eth0\/1. The\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\" \/>\n<meta property=\"og:site_name\" content=\"fibermall.com\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-27T06:57:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-29T02:07:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/qsfp-cmis-ddm-eeprom.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Catherine\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Catherine\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\"},\"author\":{\"name\":\"Catherine\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d\"},\"headline\":\"QSFP CMIS DDM EEPROM: A Practical Engineer&#8217;s Guide\",\"datePublished\":\"2026-07-27T06:57:00+00:00\",\"dateModified\":\"2026-07-29T02:07:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\"},\"wordCount\":2079,\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/qsfp-cmis-ddm-eeprom.jpg\",\"articleSection\":[\"Blog\",\"Networking\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\",\"url\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\",\"name\":\"QSFP CMIS DDM EEPROM: A Practical Engineer's Guide\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/qsfp-cmis-ddm-eeprom.jpg\",\"datePublished\":\"2026-07-27T06:57:00+00:00\",\"dateModified\":\"2026-07-29T02:07:20+00:00\",\"description\":\"Learn how QSFP CMIS, DDM, and EEPROM work together. Compare SFF-8636 and CMIS memory maps, read EEPROM with CLI tools, and interpret alarms.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#primaryimage\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/qsfp-cmis-ddm-eeprom.jpg\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/qsfp-cmis-ddm-eeprom.jpg\",\"width\":900,\"height\":600,\"caption\":\"qsfp cmis ddm eeprom\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.fibermall.com\/blog.htm\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"QSFP CMIS DDM EEPROM: A Practical Engineer&#8217;s Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"name\":\"fibermall.com\",\"description\":\"Optical Communication Expert\",\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\",\"name\":\"fibermall.com\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"width\":200,\"height\":67,\"caption\":\"fibermall.com\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d\",\"name\":\"Catherine\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g\",\"caption\":\"Catherine\"},\"description\":\"Optical Communications Engineer\",\"sameAs\":[\"https:\/\/www.fibermall.com\/\"],\"url\":\"https:\/\/www.fibermall.com\/blog.htm?author=227\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"QSFP CMIS DDM EEPROM: A Practical Engineer's Guide","description":"Learn how QSFP CMIS, DDM, and EEPROM work together. Compare SFF-8636 and CMIS memory maps, read EEPROM with CLI tools, and interpret alarms.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm","og_locale":"en_US","og_type":"article","og_title":"QSFP CMIS DDM EEPROM: A Practical Engineer's Guide","og_description":"At 2:17 a.m., Priya's phone buzzed. A 400G spine link in her Singapore data center had flapped. She logged into the switch and ran ethtool -m eth0\/1. The","og_url":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm","og_site_name":"fibermall.com","article_published_time":"2026-07-27T06:57:00+00:00","article_modified_time":"2026-07-29T02:07:20+00:00","og_image":[{"width":900,"height":600,"url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/qsfp-cmis-ddm-eeprom.jpg","type":"image\/jpeg"}],"author":"Catherine","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Catherine","Est. reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#article","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm"},"author":{"name":"Catherine","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d"},"headline":"QSFP CMIS DDM EEPROM: A Practical Engineer&#8217;s Guide","datePublished":"2026-07-27T06:57:00+00:00","dateModified":"2026-07-29T02:07:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm"},"wordCount":2079,"publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/qsfp-cmis-ddm-eeprom.jpg","articleSection":["Blog","Networking"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm","url":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm","name":"QSFP CMIS DDM EEPROM: A Practical Engineer's Guide","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#primaryimage"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/qsfp-cmis-ddm-eeprom.jpg","datePublished":"2026-07-27T06:57:00+00:00","dateModified":"2026-07-29T02:07:20+00:00","description":"Learn how QSFP CMIS, DDM, and EEPROM work together. Compare SFF-8636 and CMIS memory maps, read EEPROM with CLI tools, and interpret alarms.","breadcrumb":{"@id":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#primaryimage","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/qsfp-cmis-ddm-eeprom.jpg","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2026\/07\/qsfp-cmis-ddm-eeprom.jpg","width":900,"height":600,"caption":"qsfp cmis ddm eeprom"},{"@type":"BreadcrumbList","@id":"https:\/\/www.fibermall.com\/blog\/qsfp-cmis-ddm-eeprom-guide.htm#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fibermall.com\/blog.htm"},{"@type":"ListItem","position":2,"name":"QSFP CMIS DDM EEPROM: A Practical Engineer&#8217;s Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.fibermall.com\/blog.htm\/#website","url":"https:\/\/www.fibermall.com\/blog.htm\/","name":"fibermall.com","description":"Optical Communication Expert","publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization","name":"fibermall.com","url":"https:\/\/www.fibermall.com\/blog.htm\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","width":200,"height":67,"caption":"fibermall.com"},"image":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/bd2cf8d53f883c88f6ebaa5c3ed1258d","name":"Catherine","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/3a11235a453567962b9c9bb843b31bb4396259dd8abad3f3c3758babd287d778?s=96&d=mm&r=g","caption":"Catherine"},"description":"Optical Communications Engineer","sameAs":["https:\/\/www.fibermall.com\/"],"url":"https:\/\/www.fibermall.com\/blog.htm?author=227"}]}},"_links":{"self":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/19907","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/users\/227"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=19907"}],"version-history":[{"count":2,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/19907\/revisions"}],"predecessor-version":[{"id":19917,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/19907\/revisions\/19917"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/media\/19914"}],"wp:attachment":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=19907"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=19907"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=19907"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}