{"id":3153,"date":"2022-11-18T02:53:38","date_gmt":"2022-11-18T02:53:38","guid":{"rendered":"https:\/\/www.fibermall.com\/blog\/?p=3153"},"modified":"2022-12-16T06:50:35","modified_gmt":"2022-12-16T06:50:35","slug":"what-are-the-features-of-apc-fiber-connectors","status":"publish","type":"post","link":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm","title":{"rendered":"What are the Features of APC Fiber Connectors?"},"content":{"rendered":"<p>Fiber optic connectors are mainly composed of two parts, take our standard SC\/UPC connector to give an example. SC indicates the type of connector interface, and UPC suggests the shape of the pin end face.<\/p>\n<p>The connector&#8217;s interface is divided into SC, FC, LC, ST, MPO, and many other types. We commonly used in the project are mainly LC, FC, and SC. And the connector pin end shapes are mainly PC, UPC, and APC.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-3154\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/LC-FC-and-SC.png\" alt=\"LC, FC and SC\" width=\"500\" height=\"498\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/LC-FC-and-SC.png 260w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/LC-FC-and-SC-150x150.png 150w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/LC-FC-and-SC-120x120.png 120w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p>\n<h1><span style=\"font-size: 14pt;\"><strong><b>The difference between APC and PC, UPC<\/b><\/strong><\/span><\/h1>\n<p><strong>PC (Physical Contact)<\/strong><\/p>\n<p>The polished front face of the pin is spherical in shape. This ensures that the physical end face of the fiber is in full contact when the two connector ends meet to eliminate the effect of Fresnel reflections on the fiber end face of the system, resulting in a return loss value of 40dB or more.<\/p>\n<p><strong>UPC (Ultra Physical Contact)<\/strong><\/p>\n<p>Compared to the PC end-face, the industry-standard UPC fiber end-face has geometric requirements to achieve a return loss of 50dB or more. UPC is based on the PC end-face polishing and surface finish optimization, the end-face looks more domed.<\/p>\n<p><strong>APC (Angled Physical Contact)<\/strong><\/p>\n<p>The end face of the fiber is usually ground to an 8\u00b0\u00a0bevel, and the reflected light is reflected back to the cladding through the angle of the bevel rather than directly back to the light source. This minimizes backward reflections, resulting in a return loss of 60dB or more.<\/p>\n<p>The end faces of the three different connectors are shown below. The UPC connector has been completely replaced by the PC connector because the UPC connector has a higher loss than the PC connector. The PC connectors are called UPC connectors in daily life.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-3155\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-e1668738333303.png\" alt=\"The PC connectors are called UPC connectors in daily life\" width=\"800\" height=\"579\" \/><\/p>\n<p>Therefore, there are two types of fiber connector end faces in use: APC and UPC. The difference between the APC and UPC is that the end of the optical fiber has an 8\u00b0 bevel, and the return loss is larger. In appearance, the main colors of the two connectors are clearly different. The UPC is blue and the APC is green.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-3156\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-UPC-is-blue-and-the-APC-is-green..png\" alt=\"The UPC is blue and the APC is green.\" width=\"800\" height=\"454\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-UPC-is-blue-and-the-APC-is-green..png 426w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-UPC-is-blue-and-the-APC-is-green.-300x170.png 300w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h1><span style=\"font-size: 14pt;\"><strong><b>Return loss of movable connectors<\/b><\/strong><\/span><\/h1>\n<ol>\n<li>Definition of Return Loss (RL)<\/li>\n<\/ol>\n<p>The difference between the transmission characteristics of APC and UPC connectors is that the return loss is different. Return Loss (RL) is the decibel of the backward reflected optical power relative to the incident optical power of the optical signal at the active connector.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3157\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/Return-Loss.png\" alt=\"Return Loss\" width=\"800\" height=\"344\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/Return-Loss.png 374w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/Return-Loss-300x129.png 300w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>This formula can also be written as RL = 10lg(P1\/P0). The larger the value of RL, the smaller the reflected light power into the fiber. Obviously, the larger the RL of the movable connector, the better.<\/p>\n<p>&nbsp;<\/p>\n<ol start=\"2\">\n<li>The impact of return loss on optical communication<\/li>\n<\/ol>\n<p>In analog optical communication systems, the intensity of the optical signal varies continuously. If the intensity of the reflected signal in the optical fiber is larger, it will inevitably affect the normal signal. Therefore, the larger the RL value of the connector in the analog optical communication system, the better.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3158\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/the-intensity-of-the-optical-signal-varies-continuously.png\" alt=\"the intensity of the optical signal varies continuously\" width=\"800\" height=\"465\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/the-intensity-of-the-optical-signal-varies-continuously.png 392w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/the-intensity-of-the-optical-signal-varies-continuously-300x174.png 300w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>In digital optical communication systems using NRZ codes, there are only two types of optical signal strengths (representing &#8220;1&#8221; and &#8220;0&#8221; respectively). The reflected signal in the optical fiber does not affect the transmission of the optical signal as long as it is not strong enough to affect the determination of the signal &#8220;1&#8221;. Therefore, in digital optical communication systems using NRZ codes, there is no special requirement for the RL value of the active connector.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3159\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/no-special-requirement-for-the-RL-value-of-the-active-connector.png\" alt=\"no special requirement for the RL value of the active connector\" width=\"800\" height=\"340\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/no-special-requirement-for-the-RL-value-of-the-active-connector.png 424w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/no-special-requirement-for-the-RL-value-of-the-active-connector-300x127.png 300w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>At present, in the MAN single optical module 50G, 200G, and 400G optical communication system, line code type mainly uses PAM4 code. The PAM4 code has four signal intensities, representing 11, 10, 01, and 00. If the intensity of the reflected signal in the optical fiber is large, the judgment of the 01 signal may be affected. Therefore, the line code using the PAM4 code communication system has certain requirements for connector RL.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3160\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/the-line-code-using-PAM4-code-communication-system-has-certain-requirements-for-connector-RL.png\" alt=\"the line code using PAM4 code communication system has certain requirements for connector RL\" width=\"800\" height=\"363\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/the-line-code-using-PAM4-code-communication-system-has-certain-requirements-for-connector-RL.png 423w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/the-line-code-using-PAM4-code-communication-system-has-certain-requirements-for-connector-RL-300x136.png 300w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>In an actual optical transmission system, there are usually multiple active connections in the fiber optic transmission link, and the optical power of the reflected signal generated by each active connection accumulates in the fiber optic link. Therefore, the higher the number of active connections in a fiber optic link, the higher the return loss requirement for each connector. For example, using the PAM4 code for 40km fiber link, when the number of active connectors in the link is 2\/4\/6\/8, the return loss of active connectors should be not less than 27dB\/32dB\/35dB\/37dB respectively.<\/p>\n<p>&nbsp;<\/p>\n<ol start=\"3\">\n<li>The effect of pin end-face contamination on return loss<\/li>\n<\/ol>\n<p>When the connector end face is contaminated, it will lead to an increase in return loss. By testing the insertion loss and return loss of UPC movable connectors in the existing network, it was found that the return loss of connectors is more sensitive to end-face contamination. About 20% of the active connectors in the existing network have lower than standard return loss due to end-face contamination, while the insertion loss is only affected when the connector end face is more heavily contaminated.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3161\" src=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-effect-of-pin-end-face-contamination-on-return-loss.png\" alt=\"The effect of pin end face contamination on return loss\" width=\"800\" height=\"616\" srcset=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-effect-of-pin-end-face-contamination-on-return-loss.png 387w, https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-effect-of-pin-end-face-contamination-on-return-loss-300x231.png 300w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>The plug and return losses of the UPC movable connectors whose end faces are partially contaminated are shown in the following table.<\/p>\n<table class=\" aligncenter\" style=\"border-collapse: collapse; width: 30.6929%; height: 414px;\">\n<tbody>\n<tr style=\"height: 46px;\">\n<td style=\"width: 4.41498%; height: 46px;\">No.<\/td>\n<td style=\"width: 12.7462%; height: 46px;\">Insertion loss(dB)<\/td>\n<td style=\"width: 6.72837%; height: 46px;\">Return loss(dB)<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"width: 4.41498%; height: 46px;\">1<\/td>\n<td style=\"width: 12.7462%; height: 46px;\">0.06<\/td>\n<td style=\"width: 6.72837%; height: 46px;\">48.5<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"width: 4.41498%; height: 46px;\">2<\/td>\n<td style=\"width: 12.7462%; height: 46px;\">0.08<\/td>\n<td style=\"width: 6.72837%; height: 46px;\">47.2<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"width: 4.41498%; height: 46px;\">3<\/td>\n<td style=\"width: 12.7462%; height: 46px;\"><span style=\"color: #ff0000;\">0.34<\/span><\/td>\n<td style=\"width: 6.72837%; height: 46px;\"><span style=\"color: #ff0000;\">35.9<\/span><\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"width: 4.41498%; height: 46px;\">4<\/td>\n<td style=\"width: 12.7462%; height: 46px;\"><span style=\"color: #ff0000;\">0.32<\/span><\/td>\n<td style=\"width: 6.72837%; height: 46px;\"><span style=\"color: #ff0000;\">20.1<\/span><\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"width: 4.41498%; height: 46px;\">5<\/td>\n<td style=\"width: 12.7462%; height: 46px;\">0.06<\/td>\n<td style=\"width: 6.72837%; height: 46px;\">45.4<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"width: 4.41498%; height: 46px;\">6<\/td>\n<td style=\"width: 12.7462%; height: 46px;\">0.12<\/td>\n<td style=\"width: 6.72837%; height: 46px;\">43.3<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"width: 4.41498%; height: 46px;\">7<\/td>\n<td style=\"width: 12.7462%; height: 46px;\"><span style=\"color: #ff0000;\">0.69<\/span><\/td>\n<td style=\"width: 6.72837%; height: 46px;\">40.3<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"width: 4.41498%; height: 46px;\">8<\/td>\n<td style=\"width: 12.7462%; height: 46px;\">0.01<\/td>\n<td style=\"width: 6.72837%; height: 46px;\">45.6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h1><span style=\"font-size: 14pt;\"><strong><b>Application scenario of the APC connector<\/b><\/strong><\/span><\/h1>\n<p>The APC connector is suitable for optical communication systems with high loss requirements due to its larger loss. Such as:<\/p>\n<p>(1) CATV and other analog optical communication systems;<\/p>\n<p>(2) Metro optical communication systems with line code type PAM4 of 50G, 200G, 400G, and above;<\/p>\n<p>The previous analysis shows that PAM4 signals do not require a high level of connector loss (no less than 37dB for 8 active connections on a 40km link). However, the APC connector is recommended because the end face of connectors in actual optical links is polluted. For example, a 50G SPN system operated by an operator using an access layer cable network (8 active connections throughout the link). Because PAM4 line codes and UPC connectors are used, some systems experience errors such as increased error count, Local Fault reporting, and intermittent disconnection of 50G ports. The fault is rectified after the connector is replaced with an APC.<\/p>\n<p>(3) WDM systems using Raman fiber amplifiers.<\/p>\n<p>The fiber end face of the APC connector is 8\u00b0 beveled, and its cross-sectional area is larger than that of the UPC connector. The larger fiber cross-sectional area and larger return loss make the APC connector more suitable for carrying higher optical power. At present, single-carrier super 100G WDM systems commonly use Raman fiber amplifiers; Raman fiber amplifiers reverse output optical power up to 30dBm. If the UPC connector is used, it is easy to burn the fiber end of the connector. Therefore, equipment manuals that use Raman fiber amplifiers usually explicitly require the use of APC connectors.<\/p>\n<p>&nbsp;<\/p>\n<p>APC and UPC connectors of the same interface are essentially the same size. Although they are physically connectable, the insertion loss after the connection is large (over 4.0dB) due to the difference in pin end faces. Therefore, APC and UPC connectors cannot be mixed.<\/p>\n<p>Currently, UPC active connections are commonly used in operators&#8217; optical wiring equipment. With the line code type PAM4 communication system and the use of Raman fiber amplifier WDM system increased, the shortage of UPC active connection is increasingly exposed, fiber active connector should be transitioned from UPC to APC as soon as possible.<\/p>\n<style>\r\n\r\n        .lwrp.link-whisper-related-posts{\r\n            \r\n            margin-top: 40px;\nmargin-bottom: 30px;\r\n        }\r\n        .lwrp .lwrp-title{\r\n            \r\n            \r\n        }\r\n        .lwrp .lwrp-description{\r\n            \r\n            \r\n\r\n        }\r\n        .lwrp .lwrp-list-container{\r\n        }\r\n        .lwrp .lwrp-list-multi-container{\r\n            display: flex;\r\n        }\r\n        .lwrp .lwrp-list-double{\r\n            width: 48%;\r\n        }\r\n        .lwrp .lwrp-list-triple{\r\n            width: 32%;\r\n        }\r\n        .lwrp .lwrp-list-row-container{\r\n            display: flex;\r\n            justify-content: space-between;\r\n        }\r\n        .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n            width: calc(100% - 20px);\r\n        }\r\n        .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n            \r\n            list-style: decimal;\r\n        }\r\n        .lwrp .lwrp-list-item img{\r\n            max-width: 100%;\r\n            height: auto;\r\n        }\r\n        .lwrp .lwrp-list-item.lwrp-empty-list-item{\r\n            background: initial !important;\r\n        }\r\n        .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n        .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n            \r\n                \r\n        }\r\n        @media screen and (max-width: 480px) {\r\n            .lwrp.link-whisper-related-posts{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-title{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-description{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-multi-container{\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-multi-container ul.lwrp-list{\r\n                margin-top: 0px;\r\n                margin-bottom: 0px;\r\n                padding-top: 0px;\r\n                padding-bottom: 0px;\r\n            }\r\n            .lwrp .lwrp-list-double,\r\n            .lwrp .lwrp-list-triple{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-row-container{\r\n                justify-content: initial;\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n            .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n                \r\n                    \r\n            }\r\n        }<\/style>\r\n<div id=\"link-whisper-related-posts-widget\" class=\"link-whisper-related-posts lwrp\">\r\n            <h3 class=\"lwrp-title\">Related Posts<\/h3>    \r\n        <div class=\"lwrp-list-container\">\r\n                                            <ul class=\"lwrp-list lwrp-list-single\">\r\n                    <li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/nvidia-dgx-spark-quick-start-guide.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">NVIDIA DGX Spark Quick Start Guide: Your Personal AI Supercomputer on the Desk<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/optical-modules-data-centers.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">How to Customize Optical Modules in Data Centers?<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/interconnection-technology-data-center.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Interconnection Technology from Chip Level to Data Center<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/optical-transceiver-engine-cpo-obo.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Optical Transceiver vs Optical Engine and CPO vs OBO<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/www.fibermall.com\/blog\/pppoe-switch.htm\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Mastering Point-to-Point Protocol over Ethernet: The Ultimate Configuration Guide<\/span><\/a><\/li>                <\/ul>\r\n                        <\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Fiber optic connectors are mainly composed of two parts, take our standard SC\/UPC connector to give an example. SC indicates the type of connector interface, and UPC suggests the shape of the pin end face. The connector&#8217;s interface is divided into SC, FC, LC, ST, MPO, and many other types. We commonly used in the [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":3163,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":"","_wpscppro_dont_share_socialmedia":false,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"","_twitter_share_type":"","_linkedin_share_type":"","_pinterest_share_type":"","_linkedin_share_type_page":"","_instagram_share_type":"","_medium_share_type":"","_threads_share_type":"","_google_business_share_type":"","_selected_social_profile":[],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[2,28],"tags":[],"class_list":["post-3153","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-fiber-optic-cables"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v20.13 (Yoast SEO v25.8) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What are the Features of APC Fiber Connectors? |FiberMall<\/title>\n<meta name=\"description\" content=\"APC and UPC connectors are connectable physically, but they cannot be mixed because the insertion loss is large.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What are the Features of APC Fiber Connectors?\" \/>\n<meta property=\"og:description\" content=\"Fiber optic connectors are mainly composed of two parts, take our standard SC\/UPC connector to give an example. SC indicates the type of connector\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm\" \/>\n<meta property=\"og:site_name\" content=\"fibermall.com\" \/>\n<meta property=\"article:published_time\" content=\"2022-11-18T02:53:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-12-16T06:50:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"521\" \/>\n\t<meta property=\"og:image:height\" content=\"349\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Casey\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Casey\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm\"},\"author\":{\"name\":\"Casey\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/8a62a1260941aa13aa5900e9ea7e1342\"},\"headline\":\"What are the Features of APC Fiber Connectors?\",\"datePublished\":\"2022-11-18T02:53:38+00:00\",\"dateModified\":\"2022-12-16T06:50:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm\"},\"wordCount\":1211,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-1.png\",\"articleSection\":[\"Blog\",\"Fiber Optic Cables\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm\",\"url\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm\",\"name\":\"What are the Features of APC Fiber Connectors? |FiberMall\",\"isPartOf\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-1.png\",\"datePublished\":\"2022-11-18T02:53:38+00:00\",\"dateModified\":\"2022-12-16T06:50:35+00:00\",\"description\":\"APC and UPC connectors are connectable physically, but they cannot be mixed because the insertion loss is large.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#primaryimage\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-1.png\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-1.png\",\"width\":521,\"height\":349},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.fibermall.com\/blog.htm\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What are the Features of APC Fiber Connectors?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#website\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"name\":\"fibermall.com\",\"description\":\"Optical Communication Expert\",\"publisher\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#organization\",\"name\":\"fibermall.com\",\"url\":\"https:\/\/www.fibermall.com\/blog.htm\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"contentUrl\":\"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg\",\"width\":200,\"height\":67,\"caption\":\"fibermall.com\"},\"image\":{\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/8a62a1260941aa13aa5900e9ea7e1342\",\"name\":\"Casey\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/28096898b03bf5fa03557b33f40633b0fe4fa656c7f28e52669eca8ec4146459?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/28096898b03bf5fa03557b33f40633b0fe4fa656c7f28e52669eca8ec4146459?s=96&d=mm&r=g\",\"caption\":\"Casey\"},\"description\":\"Expert in access network, PON, GPON, etc.\",\"sameAs\":[\"https:\/\/www.fibermall.com\/\"],\"url\":\"https:\/\/www.fibermall.com\/blog.htm?author=7\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"What are the Features of APC Fiber Connectors? |FiberMall","description":"APC and UPC connectors are connectable physically, but they cannot be mixed because the insertion loss is large.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm","og_locale":"en_US","og_type":"article","og_title":"What are the Features of APC Fiber Connectors?","og_description":"Fiber optic connectors are mainly composed of two parts, take our standard SC\/UPC connector to give an example. SC indicates the type of connector","og_url":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm","og_site_name":"fibermall.com","article_published_time":"2022-11-18T02:53:38+00:00","article_modified_time":"2022-12-16T06:50:35+00:00","og_image":[{"width":521,"height":349,"url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-1.png","type":"image\/png"}],"author":"Casey","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Casey","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#article","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm"},"author":{"name":"Casey","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/8a62a1260941aa13aa5900e9ea7e1342"},"headline":"What are the Features of APC Fiber Connectors?","datePublished":"2022-11-18T02:53:38+00:00","dateModified":"2022-12-16T06:50:35+00:00","mainEntityOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm"},"wordCount":1211,"commentCount":0,"publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-1.png","articleSection":["Blog","Fiber Optic Cables"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm","url":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm","name":"What are the Features of APC Fiber Connectors? |FiberMall","isPartOf":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#primaryimage"},"image":{"@id":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#primaryimage"},"thumbnailUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-1.png","datePublished":"2022-11-18T02:53:38+00:00","dateModified":"2022-12-16T06:50:35+00:00","description":"APC and UPC connectors are connectable physically, but they cannot be mixed because the insertion loss is large.","breadcrumb":{"@id":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#primaryimage","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-1.png","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2022\/11\/The-PC-connectors-are-called-UPC-connectors-in-daily-life-1.png","width":521,"height":349},{"@type":"BreadcrumbList","@id":"https:\/\/www.fibermall.com\/blog\/features-of-apc-fiber-connectors.htm#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fibermall.com\/blog.htm"},{"@type":"ListItem","position":2,"name":"What are the Features of APC Fiber Connectors?"}]},{"@type":"WebSite","@id":"https:\/\/www.fibermall.com\/blog.htm\/#website","url":"https:\/\/www.fibermall.com\/blog.htm\/","name":"fibermall.com","description":"Optical Communication Expert","publisher":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fibermall.com\/blog.htm\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.fibermall.com\/blog.htm\/#organization","name":"fibermall.com","url":"https:\/\/www.fibermall.com\/blog.htm\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/","url":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","contentUrl":"https:\/\/www.fibermall.com\/blog\/wp-content\/uploads\/2024\/12\/cropped-Fiber-Mall-Logo.jpg","width":200,"height":67,"caption":"fibermall.com"},"image":{"@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/8a62a1260941aa13aa5900e9ea7e1342","name":"Casey","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fibermall.com\/blog.htm\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/28096898b03bf5fa03557b33f40633b0fe4fa656c7f28e52669eca8ec4146459?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/28096898b03bf5fa03557b33f40633b0fe4fa656c7f28e52669eca8ec4146459?s=96&d=mm&r=g","caption":"Casey"},"description":"Expert in access network, PON, GPON, etc.","sameAs":["https:\/\/www.fibermall.com\/"],"url":"https:\/\/www.fibermall.com\/blog.htm?author=7"}]}},"_links":{"self":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/3153","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3153"}],"version-history":[{"count":4,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/3153\/revisions"}],"predecessor-version":[{"id":3539,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/posts\/3153\/revisions\/3539"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=\/wp\/v2\/media\/3163"}],"wp:attachment":[{"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3153"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3153"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fibermall.com\/blog.htm\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3153"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}