Generally speaking, InfiniBand cards support full-duplex communication, that is, data can be transmitted in both directions at the same time. The advantage of full-duplex communication is that it can improve the efficiency and real-time performance of data transmission, but the disadvantage is that more physical lines and control logic are required.
However, InfiniBand cards can also work in half-duplex or simplex mode, depending on the requirements and design of the application layer. Half-duplex communication means that data can only be transmitted in one direction at the same time, simplex communication means that data can only be transmitted in one direction. The advantage of half duplex and simplex communication is that it can save physical lines and control logic, but the disadvantage is that it will reduce the efficiency and real-time data transmission.
People Also Ask
Related Articles

800G SR8 and 400G SR4 Optical Transceiver Modules Compatibility and Interconnection Test Report
Version Change Log Writer V0 Sample Test Cassie Test Purpose Test Objects:800G OSFP SR8/400G OSFP SR4/400G Q112 SR4. By conducting corresponding tests, the test parameters meet the relevant industry standards,

Why Is It Necessary to Remove the DSP Chip in LPO Optical Module Links?
If you follow the optical module industry, you will often hear the phrase “LPO needs to remove the DSP chip.” Why is this? To answer this question, we first need

Global 400G Ethernet Switch Market and Technical Architecture In-depth Research Report: AI-Driven Network Restructuring and Ecosystem Evolution
Executive Summary Driven by the explosive growth of the digital economy and Artificial Intelligence (AI) technologies, global data center network infrastructure is at a critical historical node of migration from

Key Design Constraints for Stack-OSFP Optical Transceiver Cold Plate Liquid Cooling
Foreword The data center industry has already adopted 800G/1.6T optical modules on a large scale, and the demand for cold plate liquid cooling of optical modules has increased significantly. To

NVIDIA DGX Spark Quick Start Guide: Your Personal AI Supercomputer on the Desk
NVIDIA DGX Spark — the world’s smallest AI supercomputer powered by the NVIDIA GB10 Grace Blackwell Superchip — brings data-center-class AI performance to your desktop. With up to 1 PFLOP of FP4 AI

RoCEv2 Explained: The Ultimate Guide to Low-Latency, High-Throughput Networking in AI Data Centers
In the fast-evolving world of AI training, high-performance computing (HPC), and cloud infrastructure, network performance is no longer just a supporting role—it’s the bottleneck breaker. RoCEv2 (RDMA over Converged Ethernet version

Comprehensive Guide to AI Server Liquid Cooling Cold Plate Development, Manufacturing, Assembly, and Testing
In the rapidly evolving world of AI servers and high-performance computing, effective thermal management is critical. Liquid cooling cold plates have emerged as a superior solution for dissipating heat from high-power processors
Related posts:
- Can the Same Module on the NDR Switch Plug an NDR Cable into One Port and an NDR 200 Splitter Cable into Another Port?
- What is the Difference Between UFM Telemetry, Enterprise and Cyber-AI?
- Any Specific Requirements for the Latency Performance of CX7 NIC?
- Is the Module on the OSFP NIC flat or Riding Heatsink?