What does “APC” or PC/UPC Mean When it Comes to Optical Connectors? Which Optical connectors use APC, and Which use UPC?

Picture of Harper Ross

Harper Ross

Answered on 3:17 am

APC and PC/UPC are two types of polish styles for the ferrules inside the optical connectors.  The ferrule is the housing for the exposed end of a fiber, designed to be connected to another fiber, or into a transmitter or receiver. The polish style affects the quality of the signal transmission and the return loss of the connector.

APC stands for Angled Physical Contact.  It means that the ferrule endface is polished at an 8° angle, which causes the reflected light to reflect at an angle into the cladding instead of straight back toward the source. This reduces the return loss and improves the performance of the connector.  APC connectors are usually green in color.

PC stands for Physical Contact. It means that the ferrule endface is polished with no angle but with a slight curvature for better core alignment.  UPC stands for Ultra Physical Contact.  It is an improvement of the PC polish with a finer surface finish and a lower return loss.  PC and UPC connectors are usually blue in color.

Different applications may require different polish styles depending on the sensitivity to return loss and the wavelength range of the signal. Generally, APC connectors are preferred for single-mode fibers, especially for higher wavelengths (above 1500 nm) and longer distances.  PC and UPC connectors are more common for multimode fibers and shorter distances.

Some examples of optical connectors that use APC polish are LC/APC, SC/APC, FC/APC, E2000/APC, etc. Some examples of optical connectors that use PC or UPC polish are LC/PC, SC/PC, FC/PC, ST/PC, MTRJ/PC, etc.

People Also Ask

1.6T and 3.2T Optical Transceivers: The Next-Gen Speed Guide for AI Data Centers

1.6T optical transceivers are emerging as the next step in high-speed connectivity for AI data centers, while 3.2T remains an early-stage technology direction. For hyperscale computing clusters, these architectures can increase bandwidth per port and support continued network scaling. Actual latency and energy-efficiency benefits depend on the transceiver design, host

USFP vs XPO vs OSFP-XD: The Next-Gen Pluggable Form Factor War

USFP, XPO, and OSFP-XD are three next-generation pluggable optical form factors designed to address growing bandwidth demands in AI networks, from 1.6T and 3.2T to 12.8T and beyond. The short answer: OSFP-XD has commercially listed 1.6T modules, XPO is being developed as a high-density, liquid-cooled solution with commercial deployment anticipated

Coherent DWDM: 400G and 800G Optical Transport Explained

Consider an illustrative 640 km regional route between two carrier hotels. Rafael’s team needs a fourfold capacity increase, and a proposal promises that moving from 400G to 800G per wavelength will deliver it. The optical modules may be capable of 800G, but the grid tells a different story. Under the

USFP vs CPO: Pluggable vs Co-Packaged Optics Compared

USFP vs CPO is a choice between two ways to move data inside an AI data center. USFP (Ultra-Dense Small Form Factor Pluggable) is a pluggable 400G-per-lane optical module you can swap in the field. CPO (co-packaged optics) integrates the optical engine directly into the switch chip to save power, at the

DWDM OADM: Passive Add-Drop Modules Explained

Every DWDM OADM a wavelength passes through introduces some optical loss. Across five cascaded nodes, that loss can consume a substantial share of the link budget—potentially comparable to tens of kilometers of fiber, depending on the OADM design. That is a detail an initial network plan can easily overlook. It

Related Articles

800g sr8 and 400g sr4

800G SR8 and 400G SR4 Optical Transceiver Modules Compatibility and Interconnection Test Report

Version Change Log Writer V0 Sample Test Cassie Test Purpose Test Objects:800G OSFP SR8/400G OSFP SR4/400G Q112 SR4. By conducting corresponding tests, the test parameters meet the relevant industry standards, and the test modules can be normally used for Nvidia (Mellanox) MQM9790 switch, Nvidia (Mellanox) ConnectX-7 network card and Nvidia (Mellanox) BlueField-3, laying a foundation for

Read More »
1.6T 3.2T optical transceiver

1.6T and 3.2T Optical Transceivers: The Next-Gen Speed Guide for AI Data Centers

1.6T optical transceivers are emerging as the next step in high-speed connectivity for AI data centers, while 3.2T remains an early-stage technology direction. For hyperscale computing clusters, these architectures can increase bandwidth per port and support continued network scaling. Actual latency and energy-efficiency benefits depend on the transceiver design, host

Read More »
USFP vs XPO vs OSFP-XD

USFP vs XPO vs OSFP-XD: The Next-Gen Pluggable Form Factor War

USFP, XPO, and OSFP-XD are three next-generation pluggable optical form factors designed to address growing bandwidth demands in AI networks, from 1.6T and 3.2T to 12.8T and beyond. The short answer: OSFP-XD has commercially listed 1.6T modules, XPO is being developed as a high-density, liquid-cooled solution with commercial deployment anticipated

Read More »
coherent dwdm

Coherent DWDM: 400G and 800G Optical Transport Explained

Consider an illustrative 640 km regional route between two carrier hotels. Rafael’s team needs a fourfold capacity increase, and a proposal promises that moving from 400G to 800G per wavelength will deliver it. The optical modules may be capable of 800G, but the grid tells a different story. Under the

Read More »
USFP vs CPO

USFP vs CPO: Pluggable vs Co-Packaged Optics Compared

USFP vs CPO is a choice between two ways to move data inside an AI data center. USFP (Ultra-Dense Small Form Factor Pluggable) is a pluggable 400G-per-lane optical module you can swap in the field. CPO (co-packaged optics) integrates the optical engine directly into the switch chip to save power, at the

Read More »
DWDM OADM

DWDM OADM: Passive Add-Drop Modules Explained

Every DWDM OADM a wavelength passes through introduces some optical loss. Across five cascaded nodes, that loss can consume a substantial share of the link budget—potentially comparable to tens of kilometers of fiber, depending on the OADM design. That is a detail an initial network plan can easily overlook. It

Read More »
Scroll to Top