Get Free Shipping on Optical Transceivers Orders Over US$300
Currency: USD
USD - US Dollar
EUR - Euro
GBP - British Pound
CAD - Canadian Dollar
AUD - Australian Dollar
JPY - Japanese Yen
SEK - Swedish Krona
NOK - Norwegian Krone
INR - Indian Rupee
BRL - Brazilian Real
RUB - Russian Ruble
Need Help?
  1. English
  2. Русский
  3. Português
  4. Español
  5. Français
  6. Deutsch
  7. 한국어
  8. العربية
  9. にほんご
Select Currency
USD - US Dollar
EUR - Euro
GBP - British Pound
CAD - Canadian Dollar
AUD - Australian Dollar
JPY - Japanese Yen
SEK - Swedish Krona
NOK - Norwegian Krone
INR - Indian Rupee
BRL - Brazilian Real
RUB - Russian Ruble
Help
Filter

Categories

Clear All

Power Supply Module

Sort by :Price: Low to High

Filter
Filter
Filter
6 Results

view {{page_size}}

Product Overview
FiberMall’s power supply module for media converter chassis delivers exactly what is needed for critical network infrastructure: AC or DC input options, hot-swap capabilities, and per-supply monitoring through the chassis management interface.

The Power Supply Is the Weakest Link

Media converter chassis consolidate up to sixteen point-to-point fiber links into a single rack unit. That density is the primary benefit, but it also concentrates risk. A standalone converter that loses power takes down one link; a chassis that loses power takes down every link it carries.

Most chassis ship with a single power supply. When that supply fails, the failure is total: all sixteen converter cards go dark, and every downstream connection—whether a building riser, a campus link, or a last-mile FTTx drop—goes down with them. The engineer on call is left to diagnose a dead chassis under pressure, often without a spare supply on the shelf.

Even when a chassis supports a second supply, the module itself is frequently treated as a buried add-on. Buyers often end up sourcing a replacement from a different vendor, guessing at voltage and connector compatibility, and simply hoping the spare fits when the 3 a.m. emergency call comes in.

What Is a Power Supply Module?

A power supply module is the removable unit that converts mains or DC input into the regulated power a media converter chassis distributes across its converter cards. In the FiberMall main chassis, it is a slide-in, hot-swappable module located at the rear of the 19-inch rack enclosure, rather than a hard-wired power brick.

There are two primary decisions that matter when selecting a module:
· AC vs. DC Input: AC modules accept standard 100–240 V AC mains, making them ideal for data center and office racks. DC modules accept -48 V (or 24 V / 48 V, as specified), which is standard for telecom central offices and -48 VDC plant environments. Choose the module based on what your rack already supplies.
· Single vs. Redundant: One module is sufficient to run the chassis; however, a second hot-swappable module will take over instantly if the first fails. For any deployment where links are mission-critical, redundancy should be the default requirement, not an optional upsell.
These modules are monitored, not passive. The chassis management interface reports each supply's type, power output, and working status in real time, ensuring a failing supply is flagged long before it can cause a dropped link.

One Supply or Two? Redundant Power Keeps Links Up

A single power supply is a single point of failure, no matter how well it is built. Redundancy is one of the main reasons a chassis is used in the first place, and power is where it matters most.

With two hot-swappable power supply modules, a single failure will never interrupt service. The working supply seamlessly carries the full load while the management interface flags the failed unit for replacement. There is no cutover time, no reboot required, and no dropped links—the switchover is automatic and entirely invisible to the network.

This is the exact same principle data centers apply to every critical device, from core switches to servers. A chassis carrying dozens of subscriber or inter-building links deserves the same level of protection. If a link is worth protecting, the chassis that carries it is worth powering redundantly.

What redundant power provides:
· No single point of failure: If one supply fails, the other carries every link without interruption.
· Per-supply visibility: Voltage, type, and working status are reported directly to your NOC through the management interface.
· Planned maintenance without downtime: You can safely swap or service one supply while the chassis stays live on the other.

Hot-Swap a Failed Supply in Seconds

The fastest fix for a failed power supply is a spare you can drop in without tools, without powering down the chassis, and without touching the links it carries. The FiberMall power supply module is designed specifically for this purpose.

Replacing a supply requires just three steps:
· Identify the failed supply: The chassis management interface flags which supply is down and reports its exact status, eliminating any guesswork about which module to pull.
· Pull the failed module: Hot-swapping means you can remove the module from the live chassis without powering down the system or disturbing any of the sixteen active fiber links.
· Insert the spare: The replacement module slides in and powers up, and the management interface immediately confirms that the new supply is back in service.
Keeping one spare module on the shelf turns what used to be an emergency call-out into a routine five-minute task. It is the cheapest insurance against the most common chassis failure mode, making the module well worth sourcing as a standalone spare rather than an afterthought.

Technical Specifications

· Product: Power supply module (for FiberMall media converter chassis)
· Form Factor: Slide-in, hot-swappable module (installs at the rear of a 19-inch rack chassis)
· Input Power: AC 100–240 V, 50–60 Hz; DC -48 V (confirm the exact range on the specific SKU)
· Redundancy: Dual-supply support, utilizing two modules for automatic failover
· Hot-Swap: Yes, the module can be replaced without powering down the chassis
· Monitoring: Per-supply reporting of type, power output, and working status via the chassis management system
· Compatibility: Designed for the FiberMall main chassis (SKU: store-17091)
· Standards: MSA and IEEE-compliant; built with certified manufacturing processes
· Applications: Data centers, telecom central offices, ISP/FTTx deployments, and enterprise networks

Frequently Asked Questions

What is a power supply module?
A power supply module is a removable unit that converts mains or DC input into the regulated power a media converter chassis distributes to its converter cards. In the FiberMall chassis, it is a slide-in, hot-swappable module that can be replaced without powering down the entire system.

What is the difference between AC and DC power supply modules?
An AC module accepts standard 100–240 V AC mains, which is typical for data center and office racks. A DC module accepts -48 V (or 24 V / 48 V) DC, typical for telecom central offices and -48 VDC plants. You should always choose the input type that your rack already provides.

What is a redundant power supply module?
Redundant power means the chassis holds two hot-swappable supply modules so that a failure in one does not interrupt service. The working module takes over the full load seamlessly, while the management interface flags the failed unit for replacement.

How do I replace a hot-swappable power supply module?
First, identify the failed supply using the management interface. Next, pull the module directly from the live chassis and insert the spare. The chassis remains powered throughout the process, and all fiber links continue to carry traffic without interruption.

Do I need one or two power supply modules?
One module is enough to run the chassis. However, for any mission-critical deployment—such as ISP, telecom, or enterprise links that you cannot afford to drop—you should add a second module for redundancy to ensure a single power failure never takes down the chassis.

Will this power supply module fit my FiberMall chassis?
Yes. This is the exact matched supply for the FiberMall main chassis (SKU: store-17091). Because FiberMall supplies both the chassis and the module together, a perfect fit and seamless compatibility are guaranteed within the ecosystem.

What input voltage does the media converter chassis power supply accept?
The module supports AC 100–240 V and DC -48 V input options. You should confirm the exact DC voltage range on your specific SKU and match the module to the power source provided by your rack.

Can I mix AC and DC power supply modules in one chassis?
You should confirm this with a FiberMall engineer based on your specific chassis configuration. While redundancy typically pairs two supplies of the identical input type, mixed configurations may be supported depending on the internal isolation of the chassis and your deployment needs.